Related Experiment Video
Updated: Feb 5, 2026

Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Enhanced Ectasia Detection Using Corneal Tomography and Biomechanics
José Ferreira-Mendes1, Bernardo T Lopes2, Fernando Faria-Correia1
1Rio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, Brazil; Ophthalmology Department, Hospital de Braga, Braga, Portugal; Life and Health Sciences Research Institute (ICVS), School of Health Sciences, University of Minho, Braga, Portugal; ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal.
The Tomographic and Biomechanical Index (TBI) accurately detects corneal ectasia, outperforming other indices. This new index shows high sensitivity and specificity for identifying ectatic corneas in diverse patient groups.
Area of Science:
- Ophthalmology
- Biomechanical analysis
- Corneal imaging
Background:
- Corneal ectasia detection is crucial for preventing vision loss.
- Existing diagnostic indices have limitations in accuracy and specificity.
- The Tomographic and Biomechanical Index (TBI) was developed to improve ectasia detection.
Purpose of the Study:
- To validate the accuracy of the Tomographic and Biomechanical Index (TBI) for detecting corneal ectasia.
- To compare the TBI's performance against other established indices like BAD-DI and CBI.
- To assess TBI's efficacy in an independent patient cohort.
Main Methods:
- Retrospective case-control study design.
- Inclusion of normal, keratoconus, and asymmetric ectasia groups (VAE-E and VAE-NT).
- Analysis of corneal topography and biomechanical data to calculate TBI, BAD-DI, and CBI.
Main Results:
- The TBI demonstrated a statistically significant higher area under the receiver operating characteristic curve (AUC) compared to all other tested parameters.
- For all cases, TBI achieved a sensitivity of 94.4% and specificity of 94.9% (AUC = 0.988).
- In the VAE-NT group, TBI showed a sensitivity of 89.5% and specificity of 91.0% (AUC = 0.960).
Conclusions:
- The TBI is a highly accurate index for differentiating normal from ectatic corneas.
- TBI surpasses the diagnostic performance of other tested indices.
- TBI shows potential in identifying ectasia susceptibility and distinguishing forme fruste keratoconus.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
04:48Establishing a Severe Corneal Inflammation Model in Rats Based on Corneal Epithelium Curettage Combined with Corneal Sutures
Published on: November 22, 2024
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...