Earable POCER: Development of a Point-of-Care Ear Sensor for Respiratory Rate Measurement
Kazuhiro Taniguchi1, Atsushi Nishikawa2,3
1Graduate School of Information Sciences, Hiroshima City University, 3-4-1 Ozukahigashi, Asaminami-ku, Hiroshima 731-3194, Japan. taniguti@hiroshima-cu.ac.jp.
Abstract:
We have carried out research and development on an earphone-type respiratory rate measuring device, earable POCER. The name earable POCER is a combination of "earable", which is a word coined from "wearable" and "ear", and "POCER", which is an acronym for "point-of-care ear sensor for respiratory rate measurement". The earable POCER calculates respiratory frequency, based on the measurement values over one minute, through the simple attachment of an ear sensor to one ear of the measured subject and displays these on a tablet terminal. The earable POCER irradiates infrared light using a light-emitting diode (LED) loaded on an ear sensor to the epidermis within the ear canal and, by receiving that reflected light with a phototransistor, it measures movement of the ear canal based on respiration. In an evaluation experiment, eight healthy subjects first breathed through the nose 12 times per minute, then 16 times per minute, and finally 20 times per minute, in accordance with the flashing of a timing instruction LED. The results of these evaluation tests showed that the accuracy of the respiratory frequency was 100% for nose breathing 12 times per minute, 93.8% at 16 times, and 93.8% at 20 times.
Related Concept Videos
Measuring Reaction Rates
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Anatomy of the Ear
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Speciation Rates
Anatomy of Respiratory System II: Lower Respiratory Tract
The Larynx
It is located between the pharynx and the trachea, acts as a passageway for air, and hosts several critical structures, such as the epiglottis, vocal cords, and glottis. The epiglottis acts as a gateway, guiding food to the...