Related Experiment Video
Updated: Feb 5, 2026

Transtubular Endoscopic Posterolateral Decompression for L5-S1 Lumbar Lateral Disc Herniation
Published on: October 14, 2022
Biomechanics of L5/S1 in Long Thoracolumbosacral Constructs: A Cadaveric Study
Bryan S Lee1,2, Kevin M Walsh3,2, Andrew T Healy4
1Cleveland Clinic, Cleveland, OH, USA.
Study Design:
In vitro cadaveric biomechanical study.
Objectives:
Despite numerous techniques employed to establish solid lumbosacral fixation, there are little biomechanical data correlating fixation methods at L5/S1 to thoracolumbosacral (TLS) construct length. We aimed to determine the optimal construct with the hypothesis that under physiological loads, lumbosacral constructs can be stabilized by L5/S1 anterior lumbar interbody fusion (ALIF) alone, without iliac screw fixation (ISF), and that TLS constructs would require ISF, with or without ALIF.
Methods:
By using a robot capable of motion in 6 axes, force-moment sensor, motion-tracking camera system and software, we simulated the spinal loading effects in flexion-extension, axial rotation, and lateral bending, and compared torques in different construct groups of T4-S1, T10-S1, and L2-S1. By conducting multidirectional flexibility testing we assessed the effects of constructs of various lengths on the L5/S1 segment.
Results:
L2-S1 constructs may be equivalently stabilized by L5/S1 ALIF alone without ISF. Longer TLS constructs exerted increasing motion at L5/S1, exhibiting trends in favor of ISF when extending to T10 and statistically improved fixation when extending to T4. Lastly, TLS constructs with ISF exhibited a statistically significant reduction in L5-S1 range of motion from the addition of ALIF when extending to T4-pelvis but not T10-pelvis.
Conclusions:
We found that ALIF alone may sufficiently support the L2-S1 construct, reducing L5/S1 range of motion and transmitting loads instead to the sacropelvis. Furthermore, ALIF was found to add significant stability to the T4-pelvis construct when added to ISF. This difference was not significant for the T10-pelvis construct.
Related Concept Videos
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Construction of Frequency Distribution
First, make a table with two columns—one with the title of the data that needs to be organized, and the other column for frequency. [Draw a third column for tally marks if needed]. Then, take a look at the items given in the data set and decide if an ungrouped frequency distribution table or a grouped frequency distribution table would be more suitable. If there are large sets of different values, then it is...
Bode Plots Construction
Design Example: Dimensioning of Concrete Masonry Construction
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...
Case Studies
Imaging Studies I: Kidney, Ureter, and Bladder Studies