Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Cementless Total Hip Arthroplasty Using the COREN Hip System: A Minimum Five-Year Follow-up Study
Hee Joong Kim1, Jeong Joon Yoo1, Wonyeong Seo1
1Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, Korea.
Purpose:
This study presents the clinical and radiological outcomes of cementless total hip arthroplasty using the COREN hip system after a minimum duration of follow-up of 5 years.
Materials And Methods:
We evaluated the results of a consecutive series of the first 200 primary total hip arthroplasties that had been performed in our hospital in 169 patients between February 2007 and April 2011. Six patients (6 hips) had died within 5 years, and 12 patients (13 hips) had been lost to follow-up, leaving a total of 151 patients (181 hips) available for the study. All patients were evaluated clinically and radiologically with special attention to thigh pain, implant fixation, radiolucent line and osteolysis around implants.
Results:
The mean Harris hip score improved from 59.4 preoperatively to 97.2 postoperatively. No patient complained of thigh pain. All implants demonstrated radiographic evidence of stable fixation by bone ingrowth without any change in position. No implant was loose radiographically or was revised. Eleven hips (7.7%) had a radiolucent line around the femoral stem. Focal osteolytic area was detected in 3 cases (2.1%). An osteolytic lesion was stabilized in 1 case and further observation was needed in 2 cases in which the lesions were detected several years after surgery. Stress shielding was observed in 80.3% of cases (first degree, 35.9%; second degree, 44.4%); there were no cases of third or fourth degree stress shielding. One case was complicated by bacterial infection and repeated dislocation.
Conclusion:
Mid-term results of total hip arthroplasty using the COREN hip system are very encouraging clinically and radiologically.
Related Concept Videos
Total Voids in Concrete
Total Internal Reflection Fluorescence Microscopy
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Static, Stagnation, Dynamic and Total Pressure
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Case Studies