Related Experiment Video
Updated: Feb 5, 2026

Simple Elimination of Background Fluorescence in Formalin-Fixed Human Brain Tissue for Immunofluorescence Microscopy
Published on: September 3, 2017
Multimodal imaging to explore endogenous fluorescence of fresh and fixed human healthy and tumor brain tissues
Hussein Mehidine1,2, Mira Sibai1, Fanny Poulon1
1IMNC Laboratory, UMR 8165-CNRS/ IN2P3, Paris-Saclay University, Orsay, France.
Abstract:
To complement a project toward label-free optical biopsy and enhanced resection which the overall goal is to develop a multimodal nonlinear endomicroscope, this multimodal approach aims to enhance the accuracy in classifying brain tissue into solid tumor, infiltration and normal tissue intraoperatively. Multiple optical measurements based on one- and two-photon spectral and lifetime autofluorescence, including second harmonic generation imaging, were acquired. As a prerequisite, studying the effect of the time of measurement postexcision on tissue's spectral/lifetime fluorescence properties was warranted, so spectral and lifetime fluorescences of fresh brain tissues were measured using a point-based linear endoscope. Additionally, a comparative study on tissue's optical properties obtained by multimodal nonlinear optical imaging microscope from fresh and fixed tissue was necessary to test whether clinical validation of the nonlinear endomicroscope is feasible by extracting optical signatures from fixed tissue rather than from freshly excised samples. The former is generally chosen for convenience. Results of this study suggest that an hour is necessary postexcision to have consistent fluorescence intensities\lifetimes. The fresh (a,b,c) vs fixed (d,e,f) tissue study indicates that while all optical signals differ after fixation. The characteristic features extracted from one- and two-photon excitation still discriminate normal brain (a,d) cortical tissue, glioblastoma (GBM) (b,e) and metastases (c,f).
Related Concept Videos
Fixing Double-strand Breaks
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Fixed Action Patterns
Segregation in Fresh Concrete
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.

