Comparison of corneal biomechanical changes after refractive surgery by noncontact tonometry: small-incision
Pernille Raevdal1,2, Jakob Grauslund1,2, Anders Højslet Vestergaard1,2
1Department of Ophthalmology, Odense University Hospital, Odense, Denmark.
Abstract:
Corneal refractive surgery disrupts corneal integrity and reduces biomechanical stability in consequence of the beneficial refractive alteration. The minimal invasive cap-based refractive procedure, small-incision lenticule extraction (SMILE), has been proposed to affect corneal integrity less than flap-based procedures, due to the fibre-sparing incision of the strong anterior corneal lamellae. Flap-based procedures include laser-assisted in situ keratomileusis (LASIK), femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and femtosecond lenticule extraction (FLEx). The purpose of this systematic review was to evaluate corneal biomechanical changes by noncontact air pulse tonometry after treatment of myopia/myopic astigmatism with SMILE compared to flap-based refractive surgery. A total of 220 publications were identified through a systematic search in PubMed and Embase. Two levels of screening identified nine studies (three randomised controlled trials (RCT) and six nonrandomised clinical trials) eligible for the review. All the nonrandomised clinical trials were graded to have an overall serious risk of bias. Measurements with the Corvis ST were not included in any of the eligible studies. The RCTs found no statistical significant differences between SMILE or flap-based procedures concerning corneal hysteresis (CH) or corneal resistance factor (CRF), as measured with the Ocular Response Analyzer. However, a greater reduction in CRF and CH was found in the flap-based group in five and two of the nonrandomised studies, respectively. The findings in this review illustrate that the presumed biomechanical advantages of a cap-based small incision could not be demonstrated in existing studies and by commercially available technology. However, studies with lower levels of evidence suggest less affection of corneal viscoelastic properties after SMILE when evaluating corneal stability by noncontact tonometry.
Related Concept Videos
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Random and Systematic Errors
Systematic Sampling Method
Systematic sampling is one of the simplest methods...