Shared-photodetector readout to improve the sensitivity of positron emission tomography
Junwei Du1, Peng Peng1, Xiaowei Bai1
1Department of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Abstract:
Sensitivity is an important performance characteristic of positron emission tomography (PET) systems. Improved sensitivity can be used to reduce injected dose, reduce scan time, or improve the signal-to-noise ratio and temporal resolution for dynamic studies. One way to improve the sensitivity of PET scanners is to reduce the gaps between detector modules. In this paper, a new signal processing method, named the shared-photodetector readout method, is proposed and evaluated. In this method, the signals generated in nearest neighbor photodetectors adjacent to the detector module of interest, were used to help identify the interaction location in the detector module of interest. Using this method, scintillator array-based detector modules with almost 100% packing fraction can be built, and the edge crystals can be clearly resolved, even when the crystals are small compared to the photodetector size. To evaluate this signal processing concept in one dimension, a detector block with four dual-ended readout detector modules, was designed. The detector block consisted of eight 4 × 4 arrays of SensL MicroFJ-30035 SiPMs coupled to both ends of a 14 × 56 array of 0.9 × 0.9 × 20 mm3 LYSO elements with a pitch size of 0.96 mm and a length of 20 mm. Performance in terms of energy resolution, flood histogram, timing resolution and depth-of-interaction resolution obtained using the shared-photodetector readout method were compared to those obtained using a conventional readout method. The results show that better over-all performance was achieved using the shared-photodetector readout method, especially at the edges and corners of the array.
More Related Videos
09:5718F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Emission Spectra
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Atomic Emission Spectroscopy: Lab
Molecular Spectroscopy: Absorption and Emission