A sensitive and reproducible screening analytical method is described for the determination of six pyrethroids (phenothrin, permethrin, cyfluthrin, cypermethrin, deltamethrin, fenvalerate) in egg and meat samples by gas chromatography and electron capture detection (GC-ECD). A fast cleanup procedure, based on solid-phase extraction has been used, ensuring reduced solvent consumption and time and allowing the simultaneous preparation of multiple sample extracts. Under the optimal chromatographic conditions, an efficient separation was obtained with a total analysis time of less than 60 min, including the extraction-purification steps. Good responses for the six pyrethroids were obtained in a range of 50-500 μg L-1, with linear coefficients higher than 0.9992. Instrumental limits of detection were between 0.22 and 0.63 μg L-1, corresponding to 0.04 and 0.13 μg kg-1 in the matrix. Detection limits in chicken eggs and various meat samples, calculated on spiked samples, were in the range 0.05-0.25 μg kg-1 and 0.07-0.23 μg kg-1, respectively. The validation results confirmed that the proposed GC-ECD method can be used as a reliable screening tool for the determination of pyrethroids in official check analyses. The method was extensively validated following the European directives, demonstrating its conformity in terms of selectivity, sensitivity, recovery, precision, and measurement uncertainty.
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....