Related Experiment Video
Updated: Feb 5, 2026

Biaxial Mechanical Characterizations of Atrioventricular Heart Valves
Published on: April 9, 2019
Single Versus Dual Lead Atrioventricular Sequential Pacing for Acquired Atrioventricular Block During Transcatheter
William K Chan1, Asaf Danon2, Harindra C Wijeysundera3
1Schulich Heart Centre and the Department of Medicine, Sunnybrook Health Sciences Centre, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
Abstract:
Atrioventricular block (AVB) after transcatheter aortic valve implantation (TAVI) is common. Pacing platforms that preserve atrioventricular (AV) synchrony may be beneficial in these patients. Single lead AV sequential pacemakers (VDD) allow AV synchrony and, by virtue of implanting a single lead, can be advantageous when compared with traditional dual lead (DDD) pacemakers. The objective of this retrospective case-controlled study was to compare the strategy of AV sequential pacing with a VDD versus DDD pacemaker in consecutive TAVI patients (n = 120) with acquired AVB. Patients were classified as receiving a VDD (n = 73) or DDD (n = 47) pacemaker. Procedure characteristics, complications, and the need for long-term ventricular pacing reported. Pacemaker implantation time (51 vs 66 minutes and p <0.001), fluoroscopy time (3.7 vs 7.8 minutes and p = 0.004), and radiation exposure (dose area product: 6.5 vs 15.3 mGy/cm2 and p = 0.006) were lower in patients receiving VDD pacemakers. Procedural complications were similar in the 2 groups. Overall, 59% of the cohort required ≥50% ventricular pacing at 1-year follow-up. In conclusion, VDD pacemaker implantation was associated with shorter procedure times, lower radiation exposure, and similar safety outcomes when compared with DDD pacemaker implantation in TAVI patients with acquired AVB.
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Phase-lead and Phase-lag Controllers
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Elements of Block Diagrams
A block diagram typically includes essential elements such as comparators, blocks, and feedback loops. Each of these elements...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction