Related Experiment Video
Updated: Feb 5, 2026

Implantation of Fibrin Gel on Mouse Lung to Study Lung-specific Angiogenesis
Published on: December 21, 2014
Identifying the predictors of needling after XEN gel implant
Neha Midha1, Harsha L Rao2, André Mermoud1
1Glaucoma Research Center, Montchoisi Clinic, Swiss Vision Network, Lausanne, Switzerland.
Purpose:
To identify factors associated with probability of needling after XEN implant.
Methods:
Analysis of data from prospective case series of patients with standalone XEN implant or combined XEN + cataract. Primary outcome was to determine whether postoperative day 1 and week 1 intraocular pressure (IOP), type of glaucoma, and glaucoma severity affected probability and number of needling interventions required.
Results:
A total of 149 eyes of 113 patients were included in the analysis. In the XEN alone group, mean IOP at day 1 and week 1 was 9.70 ± 5.43 and 10.33 ± 4.41 mmHg, respectively. Eyes with lower IOP on day 1 were less likely to require needling (Odds ratio; OR, 1.14; 95% CI, 1.02-1.28; p = 0.02). A similar association (OR, 1.15; 95% CI, 1.06-1.26; p = 0.001) was observed between day 1 IOP in and number of needling interventions. In the XEN + cataract group, mean IOPs at day 1 and week 1 were 13.75 ± 7.52 and 11.81 ± 5.36 mmHg, respectively. No significant association was noted between early postoperative IOP and probability or number of needling in this group. With IOP > 20 mmHg the probability of needling was ~ 80%. This number decreased to 35% if day 1 IOP was < 10 mmHg.
Conclusion:
Postoperative day 1 IOP is a predictor for needling in patients undergoing standalone XEN implantation. These results suggest that surgeons should not wait too long to intervene via needling if IOP in the early postoperative period is in the high teens or above. Type or severity of glaucoma did not influence the probability of needling or number of needling interventions required.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Identifying Statistically Significant Differences: The F-Test
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
In-vitro Mutagenesis