Related Experiment Video
Updated: Feb 5, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Improved Postprandial Glucose with Inhaled Technosphere Insulin Compared with Insulin Aspart in Patients with Type 1
Halis Kaan Akturk1, Janet K Snell-Bergeon1, Amanda Rewers1
11 Barbara Davis Center for Diabetes, University of Colorado Denver , Aurora, Colorado.
Background:
The majority of therapies have generally targeted fasting glucose control, and current mealtime insulin therapies have longer time action profiles than that of endogenously secreted insulin. The primary purpose of this study was to assess both glucose time-in-range (TIR: 70-180 mg/dL) and postprandial glucose excursions (PPGE) in 1-4 h using a real-time continuous glucose monitor (CGM) with Technosphere insulin (TI) versus insulin aspart in patients with type 1 diabetes (T1DM) on multiple daily injections (MDI).
Research Design And Methods:
This pilot, investigator-led, collaborative, open-label, multicenter, clinical research trial enrolled 60 patients with T1DM with HbA1c levels ≥6.5% and ≤10%. Individuals were randomized to treatment with titrated TI (n = 26) or titrated insulin aspart (n = 34), stratified by baseline HbA1c levels (≤8% or >8%). All were required to wear a real-time CGM throughout the trial. All patients in the TI group were advised to take supplemental inhalations at 1 and 2 h after meals if indicated based on postprandial glucose (PPG) values. The coprimary outcomes were assessed both in the full intent-to-treat population and in those individuals randomized to TI who were compliant with supplemental doses ≥90% of the time (n = 15). The CGM data were analyzed using linear regression models.
Results:
Overall, those treated with TI versus aspart achieved comparable TIR, but less time spent in hypoglycemia (<60 and <50 mg/dL, both P < 0.05). In the TI-compliant group (n = 15), TIR was significantly greater (62.5% ± 2.6% vs. 53.8% ± 1.7%, P = 0.009) and time in hyperglycemia >180 mg/dL was lower (34.2% ± 2.7% vs. 41.0% ± 1.7%, P = 0.045) as compared with the aspart group. PPG was also significantly lower in the TI cohort at 60 and 90 min postmeal, and PPGE were lower in the TI-compliant group as compared with the aspart group over 1-4-h postmeal (P < 0.05). In addition, there was weight gain in the aspart group compared with weight loss in the TI group (P = 0.006) despite higher prandial TI insulin dose.
Conclusions:
We conclude that using TI appropriately at mealtimes with supplemental dosing improves prandial glucose (TIR and 1-4 h) control without any increase in time in hypoglycemia or weight gain in patients with T1DM on MDI. The study results support a larger study using a treat-to-target design to confirm these findings. Clinical trial reg. no. NCT03143816, clinicaltrials.gov .
More Related Videos
05:52Insulin Injection and Hemolymph Extraction to Measure Insulin Sensitivity in Adult Drosophila melanogaster
Published on: June 30, 2011
08:32Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain
Published on: January 4, 2018
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Insulin Secretory Vesicles
Insulin: The Receptor and Signaling Pathways
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...