Related Experiment Video
Updated: Feb 5, 2026

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Improved Analysis of Manganese in Steel Samples Using Collinear Long-Short Double Pulse Laser-Induced Breakdown
Minchao Cui1,2, Yoshihiro Deguchi2,3, Zhenzhen Wang2,3
11 School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Abstract:
A long-short double pulse laser-induced breakdown spectroscopy (long-short DP-LIBS) method was employed to improve the analytical performance of LIBS for the measurement of manganese in steel samples. The long pulse with a duration of 60 μs was generated using a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser which was operated at free-running (FR) mode. To investigate the detection ability without sample preparation, the steel washers were tested using single-pulse LIBS (SP-LIBS) and long-short DP-LIBS, respectively. The measurement results show that long-short DP-LIBS was able to record clear spectra from the steel washers with a surface layer. Through the observation on the laser craters with a scanning electron microscope (SEM), the results suggest that the improvement in detection ability can be attributed to the pre-irradiation effect of long-pulse laser beam. Next, the analytical performance for quantitative measurement of manganese was evaluated employing ten standard steel samples. The results show that the linearity fit (R2) of the calibration curve is 0.988 for long-short DP-LIBS, whereas, R2 is only 0.810 for SP-LIBS under the same measurement conditions. The repeated measurement results show that the average relative standard deviation (RSD) of the tested samples is 29.3% for SP-LIBS and is 10.5% for long-short DP-LIBS. The prediction results also show that the average relative error of prediction (REP) is 94.9% for SP-LIBS and is 4.9% for long-short DP-LIBS.
More Related Videos
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
10:17Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
Related Concept Videos
Steel Fastening Techniques
Rivets are cylindrical steel fasteners with a specially designed head. During application, rivets are heated until white-hot and then inserted through pre-drilled holes in the steel sections. A pneumatic hammer is used to shape the exposed end into a second head, securing the sections together.
Bolting is another...
Steel Manufacturing
During this smelting process, limestone plays a crucial role by forming slag. Slag captures impurities within the molten iron, such...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Structural Steel Products
Once shaped, the steel's final form emerges as a continuous length, which is then segmented by a hot saw into manageable pieces. These segments...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...