Related Experiment Video
Updated: Feb 5, 2026

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024
Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty
Mina Derias1, Muhammad A Khan2, Jamie Buchanan2
1Department of Trauma and Orthopaedics, Conquest Hospital, The Ridge, Hastings, Saint Leonards-on-Sea, TN37 7RD, UK. mina.derias@nhs.net.
Introduction:
This study aims to assess the accuracy of digital templating for hip hemiarthroplasty using radiographs without calibration.
Methods:
Two independent, blinded observers retrospectively utilised digital software to template 50 consecutive patients who had hip hemiarthroplasty. The templated parameters (head size, offset and stem size) derived from pre-operative radiographs were compared to the actual prosthetic sizes used intra-operatively. Inter and intra-observer variabilities were calculated.
Results:
Both observers correctly templated the offset and head size (± 2 mm) used in 90% (n = 45) of cases. The femoral stem size (± 1 size) was correctly predicted by templating in over 84% of the cases (n = 42). Inter-observer agreement was excellent for femoral head size with an intra-class correlation coefficients (ICC) of 0.94, substantial for offset (k = 0.7) but only fair for stem size (k = 0.27). ICC values comparing the actual prostheses inserted with the template values were excellent for head size (ICC = 0.96), substantial to near perfect for offset (k = 0.78, 0.85) and fair to moderate (k = 0.24, 0.45) for stem size.
Conclusion:
Digital templating of radiographs without calibration can be used to accurately and reliably predict femoral head size and offset at a set magnification of 120%. Femoral stem size, however, is more difficult to template adequately on pre-operative radiographs without calibration.
More Related Videos
11:03Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
12:14A Duplex Digital PCR Assay for Simultaneous Quantification of the Enterococcus spp. and the Human Fecal-associated HF183 Marker in Waters
Published on: March 9, 2016
Related Concept Videos
DNA as a Genetic Template
DNA as a Genetic Template
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Predicting Molecular Geometry
Calibration Curves: Correlation Coefficient