Related Experiment Video
Updated: Feb 5, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
A running suture line for aortic valve replacement does not increase the rate of postoperative complete heart block
Ibrahim Sultan1,2, Keith A Dufendach3, Arman Kilic3,4
1Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, 5200 Centre Ave, Suite 715, Pittsburgh, PA, 15232, USA. sultani@upmc.edu.
Background:
Surgical implantation of a prosthetic aortic valve is typically done with multiple interrupted sutures. We adapted a running suture line technique for prostheses implantation to decrease the rate of complete heart block necessitating permanent pacemaker.
Methods:
374 patients undergoing isolated aortic valve replacements were identified between 2015 and 2017. Patients with preoperative heart block, patients undergoing concomitant MAZE procedure and those undergoing multivalve procedures were excluded. Interrupted technique was performed with multiple non-pledgeted sutures. Running technique was performed with three 2-0 polypropylene sutures. Propensity-score matching (caliper distance = 0.10) was used to match based on patient age, gender, BMI, diabetes mellitus, renal failure, heart failure, arrythmias, use of anti-arrhythmics, and STS PROM.
Results:
Propensity score matching yielded 103 pairs of running technique and interrupted technique patients for analysis. Within the propensity score-matched cohort, there were no differences in sustained complete heart block and need for pacemaker, 4 (3.8%) for running technique vs 3 (2.9%) for interrupted technique (p = 0.307). At 4 weeks, there was no difference in mean prosthetic aortic valve gradients calculated on transthoracic echocardiogram (6.39 ± 2.47 mmHg vs 6.46 ± 2.86, p = 0.850). There was no difference in paravalvular leak (0 (0%) vs 2 (1.9%), p = 0.070).
Conclusions:
Surgical implantation of a prosthetic aortic valve may be performed with a running suture technique without any significant increase in risk of heart block, need for permanent pacemaker or paravalvular leak. Long-term data will be critical to evaluate any development of paravalvular leaks in the future.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Anatomy of the Heart
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs

