Related Experiment Video For 18F-FDG PET/CT
Updated: Feb 5, 2026

Author Spotlight: Multiplex Immunofluorescence Combined with Spatial Image Analysis for the Clinical and Biological Assessment of the Tumor Microenvironment
Published on: June 2, 2023
Clinical Value of Combining
Rajiv Rai Sookha1, Wenhua Zhi1, Yanxia Shen2
1The Key Laboratory of Cancer Invasion and Metastasis of the Ministry of Education of China, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, P. R. China.
Abstract:
Objective: The purpose of this retrospective study was to investigate the role of 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET/CT) and evaluate if combined elevated serum tumor markers levels improve the accuracy of 18F-FDG PET/CT in detecting recurrence of cervical squamous cell carcinoma. Methods: A total number of 42 patients who were treated for cervical squamous cell carcinoma and had underwent 18F-FDG PET/CT for suspected recurrence of cervical cancer were retrospectively reviewed in this study and their clinical, pathological and serological data were collected and analyzed. The clinical value of combining 18F-FDG PET/CT with serum tumor markers was investigated. Results: Among the 42 patients, 18F-FDG PET/CT was true positive in 25 (59.5%), false positive in 5 (11.9%), true negative in 12 (28.5%) and false negative in none. The overall patient-based sensitivity, specificity, accuracy, positive predictive value and negative predictive value of 18F-FDG PET/CT in detecting recurrent cervical cancer were 100%, 70.6, 88.1%, 83.3%, and 100%, respectively. The accuracy of 18F-FDG PET/CT with combined squamous cell carcinoma antigen (SCC Ag) and carcinoembryonic antigen (CEA) elevation was 100% compared to only SCC Ag elevation and only CEA elevation, 90% and 33.3%, respectively. The positive predictive value of a positive 18F-FDG PET/CT with combined SCC Ag and CEA elevation was 100% for detection of recurrent cervical cancer. Also, the negative predictive value of a negative 18F-FDG PET/CT combined with normal SCC Ag and CEA levels was 100%. Conclusion:18F-FDG PET/CT is highly sensitive in the diagnosis of recurrent cervical cancer. When 18F-FDG PET/CT is associated with both SCC Ag and CEA elevation or only SCC Ag elevation, the accuracy is increased but not when associated with only CEA elevation. Positive 18F-FDG PET/CT associated with both tumor markers elevation can precisely predict recurrence. Moreover, normal levels of both tumor markers with a negative 18F-FDG PET/CT result may clinically reassure that a recurrence is absent.
Related Concept Videos
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Clinical Trials
There are four phases in a clinical trial. A phase one...
Impedance Combination
Combination Of Resistors
Combining Functions
Clinical Trials: Overview

