Improved image quality of low-dose CT combining with iterative model reconstruction algorithm for response assessment
Xiaoyan Xin1, Jingtao Shen2, Shangwen Yang1
1Department of Radiology, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.
Background:
To evaluate the image quality and radiation dose of low-dose (LD) computed tomography (LD-CT) combining with iterative model reconstruction (IMR) algorithm for response assessment in patients after treatment of malignant tumor compared with routine-dose CT (RD-CT).
Methods:
Forty-seven patients [mean age 57.8±10.9 years, 30 males, body mass index (BMI) 22.09±2.35 kg/m2] after treatment of malignant tumor underwent contrast-enhanced chest and abdomen CT twice for response assessment with an interval of 6 months according to clinical routine. The first CT scans were performed with RD protocol at 120 kVp and images were reconstructed with filtered back projection (FBP) algorithm; while the second scans were performed with LD protocol at 100 kVp and images were reconstructed with FBP and IMR algorithm respectively. All scans were performed using an automatic tube current modulation technique with 150 mAs as reference. Objective image quality including CT attenuation, image noise, and contrast to noise ratio (CNR), and subjective image quality including artifacts, noise, visualization of small structures and confidence of targeted lesions, as well as lesion detection were assessed and compared.
Results:
Effective radiation dose of LD-CT scans was reduced 54.8% compared to RD-CT scans (26.89±3.35 vs. 12.14±2.09 mSv). Higher CT attenuation was found in both LD-IMR and LD-FBP images compared to RD-FBP images. Better subjective image quality and CNR as well as lower objective noise were found in LD-IMR images (all, P<0.05). Two small lesions with the diameter less than 1 cm were missed in LD-FBP images, which were able to be observed in LD-IMR images.
Conclusions:
IMR is able to help more than half of reduction of radiation dose without compromising the quality of diagnostic information in patients after treatment of malignant tumors to chest and abdomen CT for response assessment.
More Related Videos
11:31Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Dose-Response Relationship: Overview
Dose-Response Relationship: Potency and Efficacy
Dose-Response Relationship: Selectivity and Specificity
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...