Related Experiment Video
Updated: Feb 5, 2026

Surgical Models of Gastroesophageal Reflux with Mice
Published on: August 25, 2015
Spotlight on the Linx™ Reflux Management System for the treatment of gastroesophageal reflux disease: evidence and
Jonathan Zadeh1, Anthony Andreoni1, Daniela Treitl1
1Department of Surgery, Mount Sinai Medical Center, Miami Beach, FL, USA, jonathan.zadeh@msmc.com.
Background:
The initial approach to gastroesophageal reflux disease (GERD) management typically involves lifestyle modification and medical therapy utilizing acid reducing agents such as histamine blockers and proton pump inhibitors. In severe cases refractory to such treatments, surgical therapy may be indicated. The gold standard for surgical treatment of GERD is the laparoscopic Nissen fundoplication. In recent years, a new technique known as magnetic sphincter augmentation (MSA) has been developed using the Linx™ Reflux Management System. This is an implantable ring of magnetic beads that is placed around the esophagus at the gastroesophageal junction to restore lower esophageal integrity. The aim of this review is to discuss the current literature regarding indications, surgical technique, efficacy, and complications of MSA using the Linx device.
Methods:
A standardized literature search was performed yielding 367 abstracts. After elimination due to duplicates between databases and irrelevance, 96 articles remained. The information found to be significant and non-redundant was included in this review.
Conclusion:
After several years of clinical application, the Linx device has been shown to not only be effective for the management of GERD but also be as effective as fundoplication. With respect to safety, the most common complication of MSA is dysphagia. This often resolved without intervention, but esophageal dilation or device explanation are occasionally necessary. Not fully appreciated in earlier reviews, erosion of the device into the esophagus appears to be the most significant complication of the device after extended follow-up. While very rare, the potentially severe consequences of this phenomenon suggest that the device should be used with some restraint and that patients should be made aware of this potential morbidity. Fortunately, in the few cases of device erosion described in the literature reviewed, the Linx device was easily and safely removed.
Related Concept Videos
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Gastroesophageal Reflux Disease I: Meaning and Pathophysiology
The Evidence for Evolution
Parkinson's Disease: Treatment
Parkinson's Disease is primarily a result of the loss of dopaminergic neurons in the substantia nigra pars compacta. The cornerstone of...
Alzheimer's Disease: Treatment
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:

