Related Experiment Video
Updated: Feb 5, 2026

Detection of Rare Genomic Variants from Pooled Sequencing Using SPLINTER
Published on: June 23, 2012
Detection of copy number variants and loss of heterozygosity from impure tumor samples using whole exome sequencing
Xiaocheng Liu1, Ao Li1,2, Jianing Xi1
1Department of Electronic Science and Technology, School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, P.R. China.
Abstract:
Using whole-exome sequencing (WES) for the detection of chromosomal aberrations from tumor samples has become increasingly popular, as it is cost-effective and time efficient. However, factors which present in WES tumor samples, including diversity in exon size, batch effect and tumor impurity, can complicate the identification of somatic mutation in each region of the exon. To address these issues, the authors of the present study have developed a novel method, PECNV, for the detection of genomic copy number variants and loss of heterozygosity in WES datasets. PECNV combines normalized logarithm ratio of read counts (Log Ratio) and B allele frequency (BAF), and then employs expectation maximization (EM) algorithm to estimate parameters involved in the models. A comprehensive assessment of PECNV of PECNV was performed by analyzing simulated datasets contaminated with different normal cell proportion and eight real primary triple-negative breast cancer samples. PECNV demonstrated superior results compared with ExomeCNV and EXCAVATOR for the detection of genomic aberrations in WES data.
Related Concept Videos
Loss of Tumor Suppressor Gene Functions
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
Histone Variants at the Centromere
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...

