Related Experiment Video
Updated: Feb 5, 2026

Intracortical Inhibition Within the Primary Motor Cortex Can Be Modulated by Changing the Focus of Attention
Published on: September 11, 2017
Repeatability of long intracortical inhibition in healthy subjects
Annika A de Goede1, Michel J A M van Putten1,2
1Department of Clinical Neurophysiology, MIRA - Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands.
Objectives:
Transcranial magnetic stimulation (TMS) is widely used to assess cortical excitability. To detect changes in excitability with longitudinal studies, it is important to validate the repeatability of excitability measures within a subject between different sessions. Repeatability studies on long intracortical inhibition (LICI) are limited and reported agreement ranges from poor to good. This study aims to evaluate the repeatability of LICI in healthy subjects using paired pulse TMS. In addition, it investigates whether LICI repeatability differs for manual and robot-guided coil positioning.
Methods:
Thirty healthy subjects (10 males, mean age 28.4 ± 8.2 years) were studied twice, approximately one week apart. Both motor cortices were stimulated with 50 paired pulses (intensity 120% of resting motor threshold) at interstimulus intervals (ISIs): 50, 100, 150, 200, 250 and 300 ms. In twenty subjects a figure-of-eight coil was positioned and held in place manually during both sessions, while in ten subjects a robot-navigated arm was used. LICI repeatability was assessed using the intraclass correlation coefficient (ICC).
Results:
For manual and robot-guided coil positioning we found a large variation in repeatability at the subject level and ISI level, ranging from poor to good agreement. On a group level, we found good repeatability for averaged LICI curves (manual: ICC = 0.91, robot-guided: ICC = 0.95), which decreased when individual curves were correlated between sessions (manual: ICC = 0.76, robot-guided: ICC = 0.84).
Conclusion:
For a correct interpretation of longitudinal study outcomes it is important to know the subject specific LICI repeatability and to analyze each ISI individually. Furthermore, the added value of robot-guided coil positioning for paired pulse TMS seems limited.
Significance:
The large variation in LICI repeatability at the subject level and ISI level should be taken into account in longitudinal studies, while robot-guided coil positioning seems unnecessary.
More Related Videos
Related Concept Videos
Bioavailability Study Design: Healthy Subjects Versus Patients
Feedback Inhibition
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Enzyme Inhibition
Cable Subjected to Concentrated Loads
Cable Subjected to a Distributed Load

