Related Experiment Video
Updated: Feb 5, 2026

Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012
A ROTEM method using APTT reagent and tissue factor as the clotting activators may better define bleeding
Shu He1, Anna Eelde2, Pia Petrini3
1Dept. of Clinical Sciences, Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden.
Abstract:
Bleeding heterogeneity observed in haemophilia A (HA) may attribute to that the available monitoring methods cannot appropriately reflect the coagulation profile. The present study aimed to develop a global approach by changing the clotting initiation way in rotational thromboelastometry (ROTEM) assay. ROTEM was run in Factor VIII (FVIII)-immune-depleted plasma to which different concentrations of recombinant VIII (rFVIII) had been added, and also in 31 patients with HA. The clotting activators were APTT reagent (1.2 × 10-3 of the dose used in the original APTT method) and recombinant tissue factor (0.02 pmol/L). In FVIII-immune-depleted plasma spiked with rFVIII, maximum velocity of coagulation reliably mirrored the rFVIII levels. This dose-response disappeared after the samples were pre-incubated with an antibody against TFPI, protein S, activated prothrombin complex concentrate or rFVIIa known to favour the extrinsic activation. In the HA patients with FVIII 0-0.21 IU/mL, APTT and ROTEM outcomes varied in significant correlations to FVIII activity; however, this correlation became non-significant when only samples with FVIII 0-0.05 IU/mL were included. Conclusions: The decreased coagulation in HA mostly result from deficiency/absence of FVIII; other pro-/anti-thrombotic proteins are also influential. The multiple effects may cause a mismatch between bleeding phenotype and FVIII concentrations. The ROTEM assay with the clotting activators i.e., tiny doses of APTT reagent and TF are more effective than the original APTT method as regards the assay sensitivity to influence by VIII activity and also to that by other pro-/anti-thrombotic proteins, showing the whole coagulation picture behind the phenotypic heterogeneity in HA.
Related Concept Videos
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Convenience Sampling Method
Convenience sampling is a non-random method of sample selection; this method selects individuals that are easily accessible and may result in biased data. For example, a marketing...
Clot Retraction and Fibrinolysis
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...

