Related Experiment Video
Updated: Feb 5, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Can one detect atrial fibrillation using a wrist-type photoplethysmographic device?
Sibylle Fallet1, Mathieu Lemay2, Philippe Renevey2
1Swiss Federal Institute of Technology, Lausanne, Switzerland. sibylle.fallet@epfl.ch.
Abstract:
This study aims at evaluating the potential of a wrist-type photoplethysmographic (PPG) device to discriminate between atrial fibrillation (AF) and other types of rhythm. Data from 17 patients undergoing catheter ablation of various arrhythmias were processed. ECGs were used as ground truth and annotated for the following types of rhythm: sinus rhythm (SR), AF, and ventricular arrhythmias (VA). A total of 381/1370/415 10-s epochs were obtained for the three categories, respectively. After pre-processing and removal of segments corresponding to motion artifacts, two different types of feature were derived from the PPG signals: the interbeat interval-based features and the wave-based features, consisting of complexity/organization measures that were computed either from the PPG waveform itself or from its power spectral density. Decision trees were used to assess the discriminative capacity of the proposed features. Three classification schemes were investigated: AF against SR, AF against VA, and AF against (SR&VA). The best results were achieved by combining all features. Accuracies of 98.1/95.9/95.0 %, specificities of 92.4/88.7/92.8 %, and sensitivities of 99.7/98.1/96.2 % were obtained for the three aforementioned classification schemes, respectively. Graphical Abstract Atrial fibrillation detection using PPG signals.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...