Fractures of the tibial pilon treated by open reduction and internal fixation (locking compression plate-less

Juan C Rubio-Suarez1, Rafael Carbonell-Escobar1, E Carlos Rodriguez-Merchan1

  • 1Department of Orthopaedic Surgery, La Paz University Hospital-IdiPaz, Madrid, Spain.

Injury
|September 17, 2018
PubMed
Abstract

Related Concept Videos

Self-Locking Screw01:16

Self-Locking Screw

A square-threaded screw jack is a mechanical device widely used for lifting heavy loads or applying considerable force. One of the key features that can make a screw jack more effective and reliable is its self-locking capability.
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
2.5K
Internal Energy02:00

Internal Energy

The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.8K
Internal Receptors01:31

Internal Receptors

Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.7K
Oxidation-Reduction Reactions03:11

Oxidation-Reduction Reactions

Oxidation–Reduction Reactions
75.7K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
844
Fixation and Sectioning01:03

Fixation and Sectioning

Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens.
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
7.9K