Related Experiment Video
Updated: Feb 5, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Electron affinities from gas chromatography electron capture detector and negative ion mass spectrometry responses
Edward C M Chen1, Edward S Chen2
1University of Houston Clear Lake, 2700 Bay Area Blvd., Houston, TX, 77059, USA.
Abstract:
The use of the electron-capture detector, ECD, to measure molecular electron affinities and kinetic parameters for reactions of thermal electrons with molecules at atmospheric pressure separated by chromatography and the sensitive and selective quantitative analysis of certain classes molecules are reviewed. The evaluated ground state electron affinities of the main group elements and diatomic molecules from slightly positive, 0+, to 3.6 eV are summarized. The electron affinities of twenty-seven superoxide states determined from pulsed discharge ECD and other methods are used to calculate one dimensional potential energy curves in agreement with theory. Advances in literature searches have uncovered ECD data in dissertations and theses and in the Russian and Japanese literature. These data, unpublished radioactive and pulsed discharge ECD thermal data from the University of Houston laboratories are used to report and evaluate electron affinities. The accuracy and precision of ECD electron affinities of organic molecules are identified and tabulated so that they can be added to compilations. A procedure for calculating the temperature dependence of electron molecule reactions is presented using kinetic and thermodynamic data. These are used toselect the most appropriate equipment and conditions for ECD analyses and physical determinations.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Electron Affinity
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Ionic Bonding and Electron Transfer