Related Experiment Video
Updated: Feb 5, 2026

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
Published on: June 19, 2018
Technical note: Rapid mineral determination in forages by X-ray fluorescence
P Berzaghi1, A Lotto2, M Mancinelli3
1Department of Animal Production and Health, University of Padua, 35020 Legnaro (PD), Italy.
Abstract:
A large portion of the cow's ration is composed of forages that can vary greatly in mineral concentrations, which may affect animal performance and health. Current methods for mineral analysis require sample destruction either through wet or dry ashing and complex analytical techniques for individual minerals. Energy dispersive X-ray fluorescence (EDXRF) is a nondestructive, multi-mineral, spectroscopy technique, which makes mineral quantification simple, direct, and affordable. The study objective was to evaluate the prediction performance of EDXRF of Na, Mg, P, S, Cl, Ca, K, Mn, Fe, Cu, and Zn concentrations in forages. Twelve certified plant samples with a wide range in mineral concentrations were used to develop calibrations, and 35 forages (18 alfalfa hays, 10 grass hays, 7 corn silages) with measured mineral concentrations, which were collected over several years from 3 proficiency programs, were used as an independent validation set. All the samples were previously dried and finely ground and were prepared by compressing them into a round dense pellet, 40 mm in diameter, using a 40-ton pneumatic laboratory press. Samples were scanned using an EDXRF instrument enhanced for lighter minerals like Na and Mg. Samples were scanned at 20 keV and at 40 KeV associated with an Al filter, for a total analysis time of approximately 6 min. Calibrations were developed with Bruker SpectraEDX (Bruker, Hamburg, Germany) software and optimized to minimize the standard error of calibration. All of the minerals had acceptable calibration performance with coefficient of determination ranging from 0.93 (P) and 0.99 (Cl, Ca, and Mn) and coefficients of variation within 5 to 14%, which are similar to the coefficients of variation of the reference analysis. The coefficients of variation for Na was an exception, with a coefficients of variation of 29%. The validation set obtained similar statistical results as that observed in calibration. The root mean square error of prediction corrected for bias was similar to the standard error of calibration, indicating that it is possible to build a robust calibrations that performed well across different type of forages by using 12 reference samples with a sufficient range in mineral concentrations that were determined accurately. A bias correction was necessary to improve prediction accuracy only for K (-0.23% dry matter) and Ca (-0.16% dry matter). Energy dispersive X-ray fluorescence demonstrated the ability to be an accurate, direct, and simple technique for forage mineral analysis.
Related Concept Videos
Optimal Foraging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Water and Mineral Acquisition
Minerals
Major...
X-ray Imaging
Essential Minerals for Bone Health
Calcium and Phosphorus
Calcium is a critical component of bones, especially in the form of calcium phosphate and calcium carbonate. Since the body cannot make calcium, it must be obtained from the diet. However, calcium cannot be absorbed from the small intestine without...

