Related Experiment Video
Updated: Feb 5, 2026

Intraoperative Assessment of Resection Margins in Oral Cavity Cancer: This is the Way
Published on: May 10, 2021
Assessment of abattoir based monitoring of PRRSV using oral fluids
M N Almeida1, J J Zimmerman1, C Wang1
1Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, Iowa, United States.
Abstract:
Various porcine reproductive and respiratory syndrome virus (PRRSV) regional elimination projects have been implemented in the U.S., but none have yet succeeded. In part, this reflects the need for efficient methods to monitor over time the progress of PRRSV status of participating herds. This study assessed the feasibility of monitoring PRRSV using oral fluids collected at the abattoir. A total of 36 pig lots were included in the study. On-farm oral fluid (n = 10) and serum (n = 10) collected within two days of shipment to the abattoir were used to establish the reference PRRSV status of the population. Oral fluids (n = 3 per lot) were successfully collected from 32 lots (89%) at the lairage. Three veterinary diagnostic laboratories (VDLs) tested the sera (VDL1 and VDL3: n = 316, VDL2: n = 315) and oral fluids (VDL1 and VDL3: n = 319, VDL2: n = 320) for PRRSV antibodies (ELISA) and RNA (rRT-PCR). Environmental samples (n = 64, 32 before and 32 after pigs were placed in lairage) were tested for PRRSV RNA at one VDL. All oral fluids (farm and abattoir) tested positive for PRRSV antibody at all VDLs. PRRSV positivity frequency on serum ranged from 92.4% to 94.6% among VDLs, with an overall agreement of 97.6%. RNA was detected on 1.3% to 1.9%, 8.1% to 17.7%, and 8.3% to 17.7% of sera, on-farm and abattoir oral fluids, respectively. Between-VDLs rRT-PCR agreement on sera and oral fluids (farm and abattoir) ranged from 97.8% to 99.0%, and 79.0% to 81.2%, respectively. Between-locations agreement of oral fluids varied from 31.3% to 50% depending on the VDL. This study reported the application of swine oral fluids collected at the abattoir for monitoring PRRSV, and describes the between-VDL agreement for PRRS testing of serum and oral fluid field samples.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Oral Cavity
Teeth: The teeth are the hardest structures in our bodies. Humans have two sets of teeth throughout their lifetime: deciduous (baby) teeth and permanent teeth. Each tooth consists of several parts: the crown (visible part), the root (embedded in the jaw), enamel (hard outer...
The Fluid Mosaic Model
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....

