Related Experiment Video
Updated: Feb 5, 2026

Two-Dimensional Super-Resolution Visualization of Rat Brain Microvasculature Using Ultrasound Localization Microscopy
Published on: March 28, 2025
High-Resolution Ultrasound Visualization of Pacinian Corpuscles
Georg Riegler1, Peter C Brugger2, Gerlinde M Gruber2
1Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
Abstract:
The aim of this study was to evaluate the possibility of visualizing Pacinian corpuscles in the palm of the hand with high-resolution ultrasound (HRUS). In this prospective study, HRUS with a high-frequency probe (22 MHz) was used. The palms of two fresh cadaveric hands were screened for potential Pacinian corpuscles. Still ultrasound images and dynamic video sequences were obtained. In five regions with large amounts of suspected Pacinian corpuscles, tissue blocks were excised and histologically processed, and corresponding slices were compared with ultrasound images. Further, the transverse diameters of five Pacinian corpuscles, at the level of the metacarpal heads in the palm, were assessed on both sides (in total 100) in healthy volunteers. On ultrasound, Pacinian corpuscles presented as echolucent dots in the subcutis, adjacent to digital nerves and vessels and located 2-3 mm beneath the surface. On histologic sections, these echolucent dots corresponded to Pacinian corpuscles with respect to their position and topographic relationships. The mean transverse diameter for all volunteers was 1.40 ± 0.23 mm (range: 0.8-2.2 mm). This study confirms the ability to reliably visualize Pacinian corpuscles with HRUS, which contributes to our basic understanding of ultrasonographically visible subcutaneous structures and may enhance the diagnosis of pathologies related to Pacinian corpuscles.
Related Concept Videos
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Visual System
Once through the pupil, the light passes through the lens, a...
Super-resolution Fluorescence Microscopy

