Related Experiment Video
Updated: Feb 5, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Complex humeral head fractures treated with blocked threaded wires: maintenance of the reduction and clinical results
Stefano Gumina1, Vittorio Candela1, Giuseppe Giannicola2
1Department of Anatomy, Histology, Legal Medicine and Orthopedics, Sapienza, University of Rome-Polo Pontino (ICOT), Latina, Italy.
Background:
Locking plates are the gold standard for treatment of 3-part humeral head fractures, although major complications range from 9% to 36%. Percutaneous techniques may allow vascular supply preservation, maintenance of fracture hematoma, scarce blood loss. Many configurations with Kirschner wires can be performed, generating confusion on result interpretation. We studied the correlation between system configuration, stability, and clinical results in patients with 3-part humeral head fractures treated with the same fixation system but with 2 different biomechanical constructs.
Materials And Methods:
There were 52 consecutive patients (19 men, 33 women; mean age, 63.1 [standard deviation, 5.6] years; range, 48-82 years) with Hertel 7 humeral head fractures. Two fixation constructs composed of 3 couples (construct A) or 4 couples (construct B) of blocked threaded wires were used in 17 and 35 patients, respectively. At the final follow-up, the individual relative Constant Score (irCS) and visual analog scale were measured. Radiographic evaluation according to the Bahr criteria was performed. Statistical analysis was performed.
Results:
The mean follow-up was 22 months. The mean irCS at the final follow-up was 89.7%. The mean irCS in patients treated with construct A and construct B was 86% and 93%, respectively (P = .043). One nonunion and 2 superficial infections occurred (6%). The postoperative reduction was excellent in 97% of patients and remained excellent in 89%. The mean postoperative neck shaft angle was 135.0° (construct A: 134.7°; construct B: 135.1°), and the final neck shaft angle was 132.9° (construct A: 131.3°; construct B: 133.8°; P = .047).
Conclusions:
The functional and radiologic outcomes obtained with percutaneous fixation or locking plates are similar; however, the percentage of major complications after percutaneous treatment is lower. Results of percutaneous fixation depend on the biomechanical construct.
Related Concept Videos
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
Oxidation-Reduction Reactions
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Maintenance of the ES Cell State
Magnetic Field Due to Two Straight Wires

