Post-cardiac Implantable Electronic Devices: Inflammation of the Pocket. Should We Be More Aggressive?
Arwa Younis1,2, Anat Wieder3,2, Roy Beinart1,2
1Leviev Heart Center, Sheba Medical Center, Tel Hashomer, Israel.
Background:
Pacemaker pocket early post-implantation inflammation (EPII) is defined as clinical signs of local erythema without any systemic signs of infection occurring early after implantation. Data on the best treatment regimen for apparent superficial EPII is scarce.
Objectives:
To investigate the prognostic value of medical treatment, rather than extraction surgery, in patients with EPII.
Methods:
Data from 6013 consecutive patients who underwent cardiac implantable electronic device (CIED) implantation or replacement from 2007-2015 were retrospectively analyzed; 40 (0.7%) presented with EPII. Our goal was the absence of major complications and to avoidance of extraction.
Results:
Patients with EPII were initially treated medically. Nineteen (47%) (group A) recovered with antibiotic treatment only. In the other 21 patients (53%) (group B), CIED extraction was performed. Group B had more major complications compared to group A (15 [71%] vs. 0 [0%], P < 0.001). The only significant difference in baseline characteristics was history of non-initial procedure. While 86% of group B patients had a previous non-initial procedure, only 53% of group A patients underwent previous replacement (P < 0.05). In multivariate analysis, previous non-initial procedure was the only predictor for need of extraction at 1 year, hazard ratio 3.5, 95% confidence interval 1.001-11.73, P < 0.05.
Conclusions:
Conservative treatment in patients with EPII after non-initial procedure can lead to serious adverse events resulting in the need for extraction. Close follow-up and aggressive treatment should be considered early in the therapeutic course.
More Related Videos
06:46Implantation of Electroencephalogram and Electrocardiogram Telemetry Devices in Neonatal Rabbit Kits
Published on: February 28, 2025
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Aggression
Inflammation
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Secondary Motives: Affiliation Motivation and Aggression Motivation
Electron Affinity
Electron Behavior
Electrons are negatively charged subatomic particles that are attracted to an orbit around the positively-charged nucleus of an atom. They reside in locations that are associated with energy levels called shells and are further organized into sub-shells and orbitals within each shell.
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the...