Related Experiment Video
Updated: Feb 5, 2026

Three-Dimensional Shape Modeling and Analysis of Brain Structures
Published on: November 14, 2019
Model-based roentgen stereophotogrammetric analysis using elementary geometrical shape models: 10 years results of an
Anne Jacobsen1, Frank Seehaus1, Yutong Hong1
1Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Rathsberger Str. 57, 91054, Erlangen, Germany.
Background:
Non-cemented acetabular cup components demonstrated different clinical performance depending on their surface texture or bearing couple. However, clinical osseointegration needs to be proved for each total joint arthroplasty (TJA) design. Aim of this study was to detect the in vivo migration pattern of a non-cemented cup design, using model-based roentgen stereophotogrammetric analysis with elementary geometrical shape models (EGS-RSA) to calculate early cup migration.
Methods:
Interchangeable applicability of the model-based EGS-RSA method next to gold standard marker-based RSA method was assessed by clinical radiographs. Afterwards, in vivo acetabular cup migration for 39 patients in a maximum follow up of 120 months (10 years) was calculated using model-based EGS-RSA.
Results:
For the axes with the best predictive capability for acetabular cup loosening, mean (±SD) values were calculated for migration and rotation of the cup. The cup migrated 0.16 (±0.22) mm along the cranio-caudal axis after 24 months and 0.36 (±0.72) mm after 120 months, respectively. It rotated - 0.61 (±0.57) deg. about the medio-lateral axis after 24 months and - 0.53 (±0.67) deg. after 120 months, respectively.
Conclusions:
Interchangeable applicability of model-based EGS-RSA next to gold standard marker-based RSA method could be shown. Model-based EGS-RSA enables an in vivo migration measurement without the necessity of TJA specific surface models. Migration of the investigated acetabular cup component indicates significant migration values along all the three axes. However, migration values after the second postoperative year were within the thresholds reported in literature, indicating no risk for later aseptic component loosening of this TJA design.
More Related Videos
Related Concept Videos
Geometric Mean
In cases of multiplicative data, the geometric mean is used for statistical analysis. First, the product of all the elements is taken. Then, if there are n elements in the...
Molecular Models
Geometric Sequences
Molecular Shapes
Two regions of electron density in a diatomic...
Mechanistic Models: Compartment Models in Individual and Population Analysis
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...

