Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Detection and quantification of trace airborne transfluthrin concentrations via air sampling and thermal desorption
Michael W C Kwan1, Jason P Weisenseel2, Nicholas Giel1
1University of Central Florida College of Medicine, Department of Internal Medicine, 6900 Lake Nona Blvd, Orlando, FL, 32827, USA.
Abstract:
A rapid thermal desorption-gas chromatography-electron ionization-mass spectrometry (TD-GC-EI-MS) method for airborne transfluthrin detection is studied. Active air sampling of 9 L over 1 h at 23 °C through a Tenax®-loaded tube resulted in efficient capture of airborne transfluthrin. Subsequent thermal desorption was employed to achieve an LOD of 2.6 ppqv (parts per quadrillion by volume). A minimum primary desorption temperature of 300 °C is necessary for optimal recovery of sample from the Tenax® adsorbent. The matrix effects of indoor air lead to an error of 10.9% and 10.5% recovery of sample (10 pg and 100 pg loaded tubes, respectively). The linear range was 74-74,000 ppqv with a correlation coefficient of 0.9981. Active air sampling of a novel passive release device revealed a ∼150 pg/L airborne concentration gradient over 1 m, providing spatial characterization of the device's performance. This efficient method allows for the remote collection of samples and rapid analysis of airborne transfluthrin from industrial applications, optimization studies of commercial products as well as domestic/household monitoring.
More Related Videos
07:21Preparation of Drosophila Larval Samples for Gas Chromatography-Mass Spectrometry GC-MS-based Metabolomics
Published on: June 6, 2018
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II