Super-resolution ultrasound imaging method for microvasculature in vivo with a high temporal accuracy

Jaesok Yu1,2, Linda Lavery1, Kang Kim3,4,5,6

  • 1Center for Ultrasound Molecular Imaging and Therapeutics, Department of Medicine and Heart and Vascular Institute, University of Pittsburgh School of Medicine and University of Pittsburgh Medical Center (UPMC), Pittsburgh, PA, 15261, USA.

Scientific Reports
|September 19, 2018
PubMed

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.6K
¹H NMR of Labile Protons: Temporal Resolution01:10

¹H NMR of Labile Protons: Temporal Resolution

Protons bonded to heteroatoms such as nitrogen and oxygen exhibit a range of chemical shift values. This is due to the varying degree of hydrogen bonding between the proton and the heteroatom in other molecules. The extent of hydrogen bonding affects the electron density around the proton, thereby giving different chemical shift values for the protons in the proton NMR spectrum.
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
1.7K
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
1.3K
Improving Translational Accuracy02:07

Improving Translational Accuracy

Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.9K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.7K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
101.8K