ATG7 and ATG9A loss-of-function variants trigger autophagy impairment and ovarian failure

Clémence Delcour1,2, Larbi Amazit1,2,3, Liliana C Patino4

  • 1Inserm U1185, Faculté de Médecine Paris Sud, Le Kremlin-Bicêtre, France.

Abstract

Related Concept Videos

Loss of Tumor Suppressor Gene Functions01:12

Loss of Tumor Suppressor Gene Functions

Tumor suppressor genes are normal genes that can slow down cell division, repair DNA mistakes, or program the cells for apoptosis in case of irreparable damage. Hence, they play an essential role in preventing the proliferation of damaged cells.
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
6.1K
Histone Variants at the Centromere02:30

Histone Variants at the Centromere

Histone variants are the histone proteins with structural and sequence variations. These variants may be regarded as “mutant” forms that replace their canonical histone counterparts in the nucleosomes. Specific post-translational modifications on the histone variants enable further chromatin complexity and regulate tissue-specific gene expression. The most common histone variants are from histone H2A, H2B, and linker histone H1 families. However, several variants of histone H3...
5.1K
Autophagy01:27

Autophagy

Autophagy is a self-digesting process by which a cell protects itself from threats both within and outside the cell, ranging from abnormal proteins to invading bacteria. In this process, obsolete components of the cell and invading microbes are degraded by hydrolytic enzymes active in an acidic environment of the lysosomal lumen.
An autophagic pathway consists of a series of signaling events activated in response to diverse stress and physiological conditions such as food deprivation,...
5.9K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
545
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
1.3K