Related Experiment Video
Updated: Feb 5, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Vitrectomy combined with posterior-segment Ahmed valve implant: A case series study
M de Frutos-Lezaun1, I Rodriguez-Agirretxe1,2, F Eder Labairu1
1Donostia University Hospital - Hospital Universitario Donostia, 117 Beguiristain Street, San Sebastian 20080, Spain.
Purpose:
To analyze the surgical outcomes and complication rates in a group of patients with refractory glaucoma who underwent simultaneous pars plana vitrectomy (PPV) and PC7 or PC8 Ahmed glaucoma valve (AGV) implantation.
Methods:
Retrospective case series study of 10 eyes in 9 patients with secondary glaucoma, refractory to other treatment, who underwent 23G-PPV and implantation of PC7 or PC8 AGV between 2012 and 2014. Study variables were postoperative BCVA, IOP and the number of glaucoma medications, which were evaluated preoperatively and at 1 day, 1 week and 1, 3, 6, and 12 months after the surgical intervention. Absolute success was defined as IOP less than 21 mmHg in the absence of any medication and qualified success if medication was needed to control IOP under 21 mmHg.
Results:
The average follow-up was 10.2 ± 2.89 months. Postoperative IOP levels decreased in all cases in comparison with preoperative values (p < 0.05). Absolute success rate was 60%, reaching 100% in terms of qualified success. Kaplan-Meier survival analysis showed 60% absolute success at 12 months. Changes in postoperative BCVA were not statistically significant in comparison with preoperative data. Early postoperative complications were athalamia, hyphema, and retinal detachment; late complications were pars plana clip extrusion and cystic bleb.
Conclusions:
PC7 and PC8 Ahmed valve implantation via pars plana is a safe and useful option in patients with secondary refractory glaucoma who are either candidates for PPV or have been previously vitrectomized.
More Related Videos
08:55Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
08:48Combining Multiple Data Acquisition Systems to Study Corticospinal Output and Multi-segment Biomechanics
Published on: January 9, 2016
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Resistors In Series
In a series circuit, the...
Series Resonance
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
Trigonometric Fourier series
The trigonometric Fourier series specifically expresses a periodic function with a defined period T using sine...
Convergence of Fourier Series
The Gibbs phenomenon refers to the persistent oscillations and overshoots that occur near discontinuities...