Related Experiment Video
Updated: Feb 5, 2026

Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
Published on: April 27, 2016
Flow-Mediated Slowing as a Methodological Alternative to the Conventional Echo-Tracking Flow-Mediated Dilation
Telmo Pereira1, Armindo Almeida1, Jorge Conde1
1Polytechnic Institute of Coimbra, Coimbra Health School, Coimbra, Portugal.
Abstract:
The Moens-Korteweg equation predicts changes in pulse wave velocity (PWV) after changes in arterial radius; therefore, an increase in arterial radius, as seen in a reactive hyperemia (RH) condition, should slow PWV over a given arterial segment. If this assumption is true, then the deceleration of PWV over the brachial artery (flow-mediated slowing [FMS]) should be an equivalent signal of endothelial function during a conventional RH flow-mediated dilation (FMD) procedure. Our aim was to compare FMS with FMD after RH in healthy individuals as part of a study that seeks to evaluate the clinical usefulness of FMS as a noninvasive approach to characterize endothelial function. This cross-sectional study included 25 healthy participants (18 women [72%]) with a mean ± SD age of 21.12±0.73 years. The FMD and FMS were simultaneously measured. A significant correlation was observed between both measures of FMS (absolute difference and percentage variation) and echo FMD: R=-0.42 (P=.04) and r=0.46 (P=.02), respectively. The FMS was shown to depend on the baseline brachial diameter, with smaller variations depicted for smaller baseline brachial diameters. It seems to be a promising and feasible method for measuring changes after RH, although further studies are needed to evaluate how this correlation holds in different clinical conditions and to demonstrate its clinical usefulness.
Related Concept Videos
Receptor-mediated Endocytosis
Receptor-mediated Endocytosis
Clathrin-Mediated Endocytosis of LDL
One well-characterized example of receptor-mediated endocytosis is the...
Nonsense-mediated mRNA Decay
Usually, Upf3 binds to an Exon Junction Complex (EJC) at mRNA splice sites. If a ribosome fully translates the mRNA,...
Gene Flow
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Carrier-Mediated Transport
Active transport involves two types of membrane-spanning transporters: uptake and efflux. Uptake transporters are expressed in the small...

