Related Experiment Video
Updated: Feb 5, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
Treatment Effects in Retinal Angiomatous Proliferation Imaged with OCT Angiography
Jan H de Jong1,2, Boy Braaf3, Sankha Amarakoon1,2
1Rotterdam Ophthalmic Institute, Rotterdam, The Netherlands.
Purpose:
This prospective case series is aimed at exploring optical coherence tomographic angiography (OCT-A) as a treatment monitoring tool in patients treated for retinal angiomatous proliferation (RAP).
Methods:
Twelve treatment-naïve RAP patients were included, with a median age of 79 years (range 65-90). Patients were imaged with an experimental 1,040-nm swept-source phase-resolved OCT-A instrument before and after treatment. Treatment consisted of either intravitreal bevacizumab or triamcinolone injections with or without photodynamic therapy (PDT). Abnormal blood flow after treatment was graded as increased, unchanged, decreased, or resolved.
Results:
OCT-A images before and after treatment could be obtained in 9 patients. The median follow-up period was 10 weeks (range 5-19). After various treatments, the RAP lesion resolved in 7 patients, in 1 patient the OCT-A depicted decreased flow in the lesion, and 1 patient showed unchanged abnormal blood flow. Monotherapy with intravitreal bevacizumab injections resolved RAP in 1 out of 2 patients. Combined therapy of bevacizumab with PDT resolved RAP in 6 out of 7 patients.
Conclusions:
OCT-A visualized resolution of abnormal blood flow in 7 out of 9 RAP patients after various short-term treatment sequences. OCT-A may become an important noninvasive monitoring tool for optimizing treatment strategies in RAP patients.
Related Concept Videos
Abnormal Proliferation
Cells Coordinate Growth and Proliferation
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Framing Effects
Biological Effects of Radiation
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...