Changes in cardiac volume determined with repeated enhanced 4DCT during chemoradiotherapy for esophageal cancer
Xue Wang1,2, Jin-Zhi Wang3, Jian-Bin Li4
1School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, Jinan, Shandong Province, China.
Background:
Concurrent chemoradiotherapy is considered curative intent treatment for patients with non-operative esophageal cancer. Radiation-induced heart damage receives much attention. We performed repeated four-dimensional computed tomography (4DCT) to detect changes in cardiac volume during radiotherapy for esophageal cancer patients, and explored potential factors responsible for those changes.
Methods:
Forty-six patients with esophageal cancer underwent enhanced 4DCT and three-dimensional (3D) CT scans before radiotherapy and every 10 fractions during treatment. The heart was contoured on 3DCT images, 4DCT end expiratory (EE) images and 4DCT maximum intensity projection (MIP) images by the same radiation oncologist. Heart volumes and other relative parameters were compared by the SPSS software package, version 19.0.
Results:
Compared with its initial value, heart volume was smaller at the 10th fraction (reduction = 3.27%, 4.45% and 4.52% on 3DCT, EE and MIP images, respectively, p < 0.05) and the 20th fraction (reduction = 6.05%, 5.64% and 4.51% on 3DCT, EE and MIP images, respectively, p < 0.05), but not at the 30th fraction. Systolic and diastolic blood pressures were reduced (by 16.95 ± 16.69 mmHg and 7.14 ± 11.64 mmHg, respectively, both p < 0.05) and the heart rate was elevated by 5.27 ± 6.25 beats/min (p < 0.05) after radiotherapy. None of the potential explanatory variables correlated with heart volume changes.
Conclusions:
Cardiac volume reduced significantly from an early treatment stage and maintained the reduction until the middle stage. The heart volume changes observed on 3DCT and 4DCT were consistent during radiotherapy. The changes in heart volume, blood pressure and heart rate may be valuable indicators of cardiac impairment and target dose changes.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Bioavailability Enhancement: Determination and Conceptual Approaches in Overcoming Bioavailability Problems
Esophageal Varices-I: Introduction
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...