Related Experiment Video
Updated: Feb 5, 2026

Invasive Behavior of Human Breast Cancer Cells in Embryonic Zebrafish
Published on: April 25, 2017
Optimization of Phase-Change Contrast Agents for Targeting MDA-MB-231 Breast Cancer Cells
Kyle P Hadinger1, Joseph P Marshalek1, Paul S Sheeran2
1Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA.
Abstract:
Breast cancer remains a leading cause of death for women throughout the world. Recent advances in medical imaging technologies and tumor targeting agents signify vast potential for progress toward improved management of this global problem. Phase-change contrast agents (PCCAs) are dynamic imaging agents with practical applications in both the research and clinical settings. PCCAs possess characteristics that allow for cellular uptake where they can be converted from liquid-phase PCCAs to gaseous microbubbles via ultrasound energy. Previously, we reported successful internalization of folate-targeted PCCAs in MDA-MB-231 breast cancer cells followed by ultrasound-mediated activation to produce internalized microbubbles. This study examines the binding, internalization and activation of folate-receptor targeted PCCAs in MDA-MB-231 breast cancer cells as a function of gaseous core compositions, incubation time and ultrasound exposure period. In vitro results indicate that internalization and ultrasound-mediated activation of PCCAs were significantly greater using a 50:50 mixture of decafluorobutane:dodecafluoropentane compared with other core compositions: 50:50 octafluoropropane:decafluorobutane (p < 0.0001), decafluorobutane (p < 0.04) and dodecafluoropentane (p < 0.0001). Furthermore, it was found that PCCAs composed of perfluorocarbons with higher boiling points responded with greater activation efficiency when exposed to 12 s of ultrasound exposure as opposed to 4 s of ultrasound exposure. When evaluating different incubation times, it was found that incubating the PCCAs with breast cancer cells for 60 min did not produce significantly greater internalization and activation compared with incubation for 10 min; this was concluded after comparing the number of microbubbles present per cell before ultrasound versus post-ultrasound, and finding a ratio of intracellular microbubbles post-ultrasound/pre-ultrasound, 3.46 versus 3.14, respectively. The data collected in this study helps illustrate further optimization of folate-receptor targeted PCCAs for breast cancer targeting and imaging.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Targeted Cancer Therapies
There are several types of targeted therapies against...
Phase Transitions
Phase Diagrams
Le Chatelier's Principle: Changing Concentration
Global Climate Change

