Background:
Children with severe spinal deformity frequently are managed with growth-friendly implants. After initial surgery, externally controlled magnetic rods allow spinal deformity correction during growth without further surgical intervention. The ability to lengthen the spine without additional surgical procedures is especially beneficial in high-risk children, such as those with spinal muscular atrophy (SMA). The purpose of the present study was to assess the level of control of spinal deformity in a homogeneous group of patients with SMA who were managed with magnetically controlled implants for 2 years.
Methods:
This prospective, nonrandomized study included 21 non-ambulatory children with type-II SMA and progressive scoliosis who were managed bilaterally with a magnetically controlled implant that was inserted parallel to the spine with use of rib-to-pelvis hook fixation. Radiographic measurements of scoliotic curves, kyphosis, lordosis, pelvic obliquity, and spinal length were performed before and after implantation of the magnetically controlled device and during external lengthening. The mean duration of follow-up was 2 years.
Results:
The mean main curve of patients without prior vertical expandable prosthetic titanium rib (VEPTR) treatment decreased from 70° before implantation of the magnetically controlled device to 30° after implantation of the device. Correction was maintained during the follow-up period, with a mean curve of 31° at the time of the latest follow-up at 2.2 years. Pelvic obliquity was surgically corrected by 76% (from 17° to 4°) and remained stable during follow-up. Thoracic kyphosis could not be corrected within the follow-up period. Spinal length of children without prior spinal surgery increased by >50 mm immediately after device implantation and steadily increased at a rate of 13.5 mm/yr over the course of treatment. During treatment, 4 general complications occurred and 6 lengthening procedures failed, with 3 patients requiring surgical revision.
Conclusions:
Bilateral implantation of an externally controlled magnetic rod with rib-to-pelvis fixation represents a safe and efficient method to control spinal deformity in children with SMA, achieving sufficient and stable curve correction as well as increased spinal length. The complication rate was lower than those that have been described for VEPTR and other growing rod instrumentation strategies.
Level Of Evidence:
Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Related Concept Videos
Magnetic Force Between Two Parallel Currents
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and the vector product of the length vector along the current element and the field due to the first conductor. According to the...
The Muscular System
Parallel Resonance
Parallel Processing
Resistors In Parallel
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...