Related Experiment Video
Updated: Feb 5, 2026

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
Published on: February 1, 2022
Relationship of Time-Activity-Adjusted Particle Number Concentration with Blood Pressure
Laura Corlin1,2, Shannon Ball3,4, Mark Woodin5,6
1Department of Civil and Environmental Engineering, Tufts University School of Engineering, 200 College Ave, Medford, MA 02155, USA. lauracorlin25@gmail.com.
Abstract:
Emerging evidence suggests long-term exposure to ultrafine particulate matter (UFP, aerodynamic diameter < 0.1 µm) is associated with adverse cardiovascular outcomes. We investigated whether annual average UFP exposure was associated with measured systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP), and hypertension prevalence among 409 adults participating in the cross-sectional Community Assessment of Freeway Exposure and Health (CAFEH) study. We used measurements of particle number concentration (PNC, a proxy for UFP) obtained from mobile monitoring campaigns in three near-highway and three urban background areas in and near Boston, Massachusetts to develop PNC regression models (20-m spatial and hourly temporal resolution). Individual modeled estimates were adjusted for time spent in different micro-environments (time-activity-adjusted PNC, TAA-PNC). Mean TAA-PNC was 22,000 particles/cm³ (sd = 6500). In linear models (logistic for hypertension) adjusted for the minimally sufficient set of covariates indicated by a directed acyclic graph (DAG), we found positive, non-significant associations between natural log-transformed TAA-PNC and SBP (β = 5.23, 95%CI: -0.68, 11.14 mmHg), PP (β = 4.27, 95%CI: -0.79, 9.32 mmHg), and hypertension (OR = 1.81, 95%CI: 0.94, 3.48), but not DBP (β = 0.96, 95%CI: -2.08, 4.00 mmHg). Associations were stronger among non-Hispanic white participants and among diabetics in analyses stratified by race/ethnicity and, separately, by health status.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
The Integrated Rate Law: The Dependence of Concentration on Time
Measurement of Blood Pressure

