Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

894
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
894
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.7K
3.7K
Improving Translational Accuracy02:07

Improving Translational Accuracy

14.9K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.9K
Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

615
Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
615
Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

23.6K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
23.6K
The Scientific Method03:50

The Scientific Method

66.9K
Chemistry is an empirical science. Scientists often pose questions to understand the chemistry in everyday life and seek answers to these questions. To achieve this, scientists follow a definitive series of steps that together make up the Scientific Method. This approach involves making observations, asking questions, building a hypothesis, conducting experiments, analyzing results, and forming a conclusion. 
66.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An anesthetic protocol for preserving functional network structure in the marmoset monkey brain.

Imaging neuroscience (Cambridge, Mass.)·2025
Same author

Perioperative use of potent opioids in cats.

The Veterinary record·2025
Same author

Detecting the contribution of V5/MT in reading, reading-related tasks, eye-movements and EEG-oscillations in children and adolescents with developmental dyslexia via high-definition tDCS: a protocol study.

BMC psychology·2025
Same author

Temporal dynamics of offline transcranial ultrasound stimulation.

Current research in neurobiology·2025
Same author

Unstable foveation's impact on reading, object tracking, and its implications for diagnosing and intervening in reading difficulties.

Scientific reports·2025
Same author

A Quality Improvement Initiative to Reduce Surgical Site Infections in Pediatric Patients Undergoing Cardiothoracic Surgery.

Pediatric quality & safety·2025
Same journal

Detection of cochlear microphonic for differential diagnosis between auditory neuropathy mice and noise-induced sensorineural hearing loss mice.

Journal of neuroscience methods·2026
Same journal

Assessment metrics for pain control in rats: A methodological commentary.

Journal of neuroscience methods·2026
Same journal

Infant EEG preprocessing pipelines: A capability framework and current gaps in practice.

Journal of neuroscience methods·2026
Same journal

Methods for measuring neural activity during voluntary wheel running.

Journal of neuroscience methods·2026
Same journal

Serotype-dependent differences in AAV cellular transduction rates in the hypothalamus of Arctic ground squirrels.

Journal of neuroscience methods·2026
Same journal

Rapid generation of human sensory neurons from iPSC for modeling of peripheral neuropathies.

Journal of neuroscience methods·2026
See all related articles

Related Experiment Video

Updated: Feb 5, 2026

Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research
06:33

Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research

Published on: February 9, 2024

1.8K

Improved methods for MRI-compatible implants in nonhuman primates.

Michael Ortiz-Rios1, Marcus Haag1, Fabien Balezeau1

  • 1Institute of Neuroscience, Henry Welcome Building, Medical School, Framlington Place, Newcastle upon Tyne, NE2 4HH, United Kingdom.

Journal of Neuroscience Methods
|September 21, 2018
PubMed
Summary
This summary is machine-generated.

This study introduces novel MRI-compatible implants for nonhuman primates, enhancing functional magnetic resonance imaging (fMRI) signal quality without acrylic. The new head stabilization method improves neuroimaging and animal welfare in neuroscience research.

Keywords:
AcrylicElectrophysiologyFunctional magnetic resonance imaging (fMRI)Hydroxyapatite (HA)ImplantMacaqueOsseointegrationPolyetheretherketone (PEEK)

More Related Videos

A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates
08:41

A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates

Published on: July 17, 2020

5.4K
Preparation and Gene Modification of Nonhuman Primate Hematopoietic Stem and Progenitor Cells
11:16

Preparation and Gene Modification of Nonhuman Primate Hematopoietic Stem and Progenitor Cells

Published on: February 15, 2019

8.1K

Related Experiment Videos

Last Updated: Feb 5, 2026

Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research
06:33

Author Spotlight: Streamlined Brain and Skull Modeling for Enhanced Neurosurgical Planning in NHP Research

Published on: February 9, 2024

1.8K
A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates
08:41

A MRI-Based Toolbox for Neurosurgical Planning in Nonhuman Primates

Published on: July 17, 2020

5.4K
Preparation and Gene Modification of Nonhuman Primate Hematopoietic Stem and Progenitor Cells
11:16

Preparation and Gene Modification of Nonhuman Primate Hematopoietic Stem and Progenitor Cells

Published on: February 15, 2019

8.1K

Area of Science:

  • Neuroscience
  • Biomedical Engineering
  • Medical Imaging

Background:

  • Nonhuman primates (NHPs) commonly use headposts for head stabilization during electrophysiology and fMRI.
  • Traditional acrylic implants pose limitations for MRI compatibility and signal quality.

Purpose of the Study:

  • To develop improved, MRI-compatible head implants for NHPs.
  • To enhance functional magnetic resonance imaging (fMRI) signal quality without contrast agents.

Main Methods:

  • Customized implants manufactured from PEEK using computer numerical control (CNC) machining.
  • Hydroxyapatite coating for osseointegration and ceramic screws for skull attachment.
  • Surgical implantation technique minimizing subcutaneous disruption.

Main Results:

  • Improved blood oxygen level dependent (BOLD) fMRI signal quality compared to acrylic implants.
  • Long-term implant stability (>1 year) with no granulation tissue.
  • Preserved fMRI compatibility without contrast agents.

Conclusions:

  • The novel implant methodology enhances fMRI signal in NHPs.
  • Osseointegrated implants offer superior stability and promote animal well-being.
  • This technique advances NHP research by overcoming limitations of previous head stabilization methods.