Performance of Commercially Available Serological Screening Tests for Human T-Cell Lymphotropic Virus Infection in
Vanessa da Silva Brito1, Fred Luciano Neves Santos2, Noilson Lazaro Sousa Gonçalves1,2
1Integrated and Multidisciplinary HTLV Center, Bahiana School of Medicine and Public Health (EBMSP), Salvador, Bahia, Brazil.
Serological screening for human T-cell lymphotropic virus type 1 (HTLV-1) is usually performed using enzyme-linked immunosorbent assay (ELISA), particle agglutination, or chemiluminescence assay kits. Due to an antigen matrix improvement entailing the use of new HTLV antigens and changes in the format of HTLV screening tests, as well as newly introduced chemiluminescence assays (CLIAs), a systematic evaluation of the accuracy of currently available commercial tests is warranted. We aimed to assess the performance of commercially available screening tests for HTLV infection diagnosis. A diagnostic accuracy study was conducted on a panel of 397 plasma samples: 200 HTLV-negative plasma samples, 170 HTLV-positive plasma samples, and 27 plasma samples indeterminate by Western blotting (WB). WB-indeterminate samples (i.e., those yielding no specific bands for HTLV-1 and/or HTLV-2) were assessed by PCR, and the results were used to compare agreement among the commercially available ELISA screening tests. For performance analysis, WB-indeterminate samples were excluded, resulting in a final study panel of 370 samples. Three ELISA kits (Murex HTLV-1/2 [Murex], anti-HTLV-1/2 SYM Solution [SYM Solution], and Gold ELISA HTLV-1/2 [Gold ELISA]) and one CLIA kit (Architect rHTLV-1/2) were evaluated. All screening tests demonstrated 100% sensitivity. Concerning the HTLV-negative samples, the SYM Solution and Gold ELISA kits had specificity values of >99.5%, while the Architect rHTLV-1/2 test presented 98.1% specificity, followed by Murex, which had a specificity of 92.0%. Regarding the 27 samples with WB-indeterminate results, after PCR confirmation, all ELISA kits showed 100% sensitivity but low specificity. Accuracy findings were corroborated by the use of Cohen's kappa value, which evidenced slight and fair agreement between PCR analysis and ELISAs for HTLV infection diagnosis. Based on the data, we believe that all evaluated tests can be safely used for HTLV infection screening.
Serological screening for human T-cell lymphotropic virus type 1 (HTLV-1) is usually performed using enzyme-linked immunosorbent assay (ELISA), particle agglutination, or chemiluminescence assay kits. Due to an antigen matrix improvement entailing the use of new HTLV antigens and changes in the format of HTLV screening tests, as well as newly introduced chemiluminescence assays (CLIAs), a systematic evaluation of the accuracy of currently available commercial tests is warranted. We aimed to assess the performance of commercially available screening tests for HTLV infection diagnosis. A diagnostic accuracy study was conducted on a panel of 397 plasma samples: 200 HTLV-negative plasma samples, 170 HTLV-positive plasma samples, and 27 plasma samples indeterminate by Western blotting (WB). WB-indeterminate samples (i.e., those yielding no specific bands for HTLV-1 and/or HTLV-2) were assessed by PCR, and the results were used to compare agreement among the commercially available ELISA screening tests. For performance analysis, WB-indeterminate samples were excluded, resulting in a final study panel of 370 samples. Three ELISA kits (Murex HTLV-1/2 [Murex], anti-HTLV-1/2 SYM Solution [SYM Solution], and Gold ELISA HTLV-1/2 [Gold ELISA]) and one CLIA kit (Architect rHTLV-1/2) were evaluated. All screening tests demonstrated 100% sensitivity. Concerning the HTLV-negative samples, the SYM Solution and Gold ELISA kits had specificity values of >99.5%, while the Architect rHTLV-1/2 test presented 98.1% specificity, followed by Murex, which had a specificity of 92.0%. Regarding the 27 samples with WB-indeterminate results, after PCR confirmation, all ELISA kits showed 100% sensitivity but low specificity. Accuracy findings were corroborated by the use of Cohen's kappa value, which evidenced slight and fair agreement between PCR analysis and ELISAs for HTLV infection diagnosis. Based on the data, we believe that all evaluated tests can be safely used for HTLV infection screening.
Related Concept Videos
What are Viruses?
Pathophysiology of Cardiac Performance
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Genetic Screens
Forward genetic screens
Forward or “classical” genetic screens involve creating random mutations in an organism’s DNA using radiation, mutagens, or insertion of additional bases, which...
Testes: Histology
The spermatogenic cells, responsible for producing sperm, are...
Complementation Tests
Organisms heterozygous for different mutations are crossed pairwise in all combinations. If present on different genes, the mutations can complement each other by providing the missing...