[Simulation of Concentration Measurement of SO(2), NO(2) and Particles Simultaneously by Differential Optical

Related Concept Videos

meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H01:13

meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H

All meta-directing substituents are deactivating groups. These substituents withdraw electrons from the aromatic ring, making the ring less reactive toward electrophilic substitution. For example, the nitration of nitrobenzene is 100,000 times slower than that of benzene because of the deactivating effect of the nitro group. The first step in an electrophilic aromatic substitution is the addition of an electrophile to form a resonance-stabilized carbocation. The energy diagrams for...
6.7K
2° Amines to N-Nitrosamines: Reaction with NaNO201:20

2° Amines to N-Nitrosamines: Reaction with NaNO2

Secondary amines react with nitrous acid to form N-nitrosamines, as depicted in Figure 1. Nitrous acid, a weak and unstable acid, is formed in situ from an aqueous solution of sodium nitrite and strong acids, such as hydrochloric acid or sulfuric acid, in cold conditions. In the presence of an acid, the nitrous acid gets protonated. The subsequent loss of water results in the formation of the electrophile known as nitrosonium ion.
5.5K
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.1K
Molecular Spectroscopy: Absorption and Emission01:14

Molecular Spectroscopy: Absorption and Emission

Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels.  Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
4.5K
Atomic Absorption Spectroscopy: Overview01:27

Atomic Absorption Spectroscopy: Overview

Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
3.5K
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
1.7K