A Compressed-Sensing Based Blind Deconvolution Method for Image Deblurring in Dental Cone-Beam Computed Tomography
K S Kim1, S Y Kang1, C K Park1
1Department of Radiation Convergence Engineering, Yonsei University, Wonju, 26493, Republic of Korea.
Abstract:
In cone-beam computed tomography (CBCT), reconstructed images are inherently degraded, restricting its image performance, due mainly to imperfections in the imaging process resulting from detector resolution, noise, X-ray tube's focal spot, and reconstruction procedure as well. Thus, the recovery of CBCT images from their degraded version is essential for improving image quality. In this study, we investigated a compressed-sensing (CS)-based blind deconvolution method to solve the blurring problem in CBCT where both the image to be recovered and the blur kernel (or point-spread function) of the imaging system are simultaneously recursively identified. We implemented the proposed algorithm and performed a systematic simulation and experiment to demonstrate the feasibility of using the algorithm for image deblurring in dental CBCT. In the experiment, we used a commercially available dental CBCT system that consisted of an X-ray tube, which was operated at 90 kVp and 5 mA, and a CMOS flat-panel detector with a 200-μm pixel size. The image characteristics were quantitatively investigated in terms of the image intensity, the root-mean-square error, the contrast-to-noise ratio, and the noise power spectrum. The results indicate that our proposed method effectively reduced the image blur in dental CBCT, excluding repetitious measurement of the system's blur kernel.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Blind Procedures
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Blinding
Area Computation by the Alternative Coordinate Method