Related Experiment Video
Updated: Feb 5, 2026

Laparoscopic Anterior Right Hepatectomy: A Single-Center Experience
Published on: December 4, 2023
Robotic single-site myomectomy: A single-center experience of 101 consecutive cases
Miseon Kim1, Mi Kyoung Kim1, Mi-La Kim1
1Department of Obstetrics and Gynecology, CHA Gangnam Medical Center, CHA University College of Medicine, Seoul, Republic of Korea.
Background:
To evaluate the feasibility and clinical outcomes of robotic single-site myomectomy (RSSM) for uterine myoma.
Methods:
Medical records of 101 consecutive women who underwent RSSM were retrospectively reviewed, and patient characteristics and surgical outcomes were evaluated. The surgical outcomes were compared by the phase in learning curve (early phase of <10 cases vs late phase of ≥10 cases) and time flow.
Results:
A total of 47 (46.5%) women had multiple myomas, and a median two (1-12) myomas were retrieved. The largest myoma was averagely measured as 6.2 ± 1.7 cm, and the mean weight of the total retrieved myomas was 114.0 ± 84.4 g. No patients received a transfusion or had operation-related complications. Cases in the late phase showed shorter port placement time and docking time than those in the early phase.
Conclusions:
Our data suggest that robotic single-site surgery is a feasible therapeutic option for uterine myoma.
More Related Videos
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
03:07Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
Related Concept Videos
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Angular Momentum: Single Particle
Single-pass Transmembrane Proteins
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...