Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Effect of the support systems' compliance on total hip modular taper seating stability
Laura Scholl1, David Pierre2, Raga Rajaravivarma1
11 Stryker Orthopaedics, Mahwah, NJ, USA.
Abstract:
Assembly of a femoral head onto the stem remains non-standardized. The literature shows altering mechanical conditions during seating affects taper strength and lower assembly load may increase fretting corrosion during cyclic tests. This suggests overall performance may be affected by head assembly method. The purpose of this test was to perform bench-top studies to determine influence of peak force magnitude, load rate, and compliance of the system's support structure on initial stability of the taper. Custom manufactured CoCrMo femoral heads and Ti-6Al-4V taper analog samples were assembled with varying peak force magnitudes (2-10.1 kN), load rates (quasi-static vs impaction), and system compliance (rigid vs compliant). A clinically-relevant system compliance design was based off of force data collected during a cadaver impaction study. Tensile loads were then applied to disassemble the taper and quantify initial taper stability. Results indicated that taper stability (assessed by disassembly forces) increased linearly with assembly force and load rate did not have a significant effect on taper stability. When considering system compliance, a 42%-50% larger input energy, dependent on assembly force, was required in the compliant group to achieve a comparable impaction force to the rigid group. Even when this impaction force was achieved, the correlation between the coefficient, defined as distraction force divided by assembly load, was significantly reduced for the compliant test group. The compliant setup was intended to simulate a surgical scenario where patient and surgical factors may influence the resulting compliance. Based on results, surgical procedure and patient variables may have a significant effect on initial taper stability.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
08:40Surgical Technique of the 3-Dimensional-printed Personalized Hip Implant for the Treatment of Canine Hip Dysplasia
Published on: April 19, 2024
Related Concept Videos
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying a...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...