Related Experiment Video
Updated: Feb 5, 2026

Induction of Right Ventricular Failure by Pulmonary Artery Constriction and Evaluation of Right Ventricular Function in Mice
Published on: May 13, 2019
Outcomes of patients with right ventricular failure requiring short-term hemodynamic support with the Impella RP
Mark Anderson1, D Lynn Morris2, Daniel Tang3
1Division of Cardiothoracic Surgery, Einstein Healthcare Network, Philadelphia, Pennsylvania, USA.
Background:
Right ventricular failure (RVF) after myocardial infarction, cardiotomy, or left ventricular assist device (LVAD) implantation increases morbidity and mortality. RVF also contributes to prolonged length of hospital stay and higher costs of care. The aim of this study was to evaluate the efficacy and safety of the Impella RP (Abiomed, Danvers, MA) in patients with severe RVF in these clinical settings.
Methods:
This is a prospective cohort study of patients with severe RVF treated with a percutaneous right ventricular assist device (RVAD). Sixty patients with RVF refractory to medical treatment received the Impella RP device at 14 United States institutions as part of the Impella RP pre‒ and post‒market approval studies. The study population included 2 cohorts: Cohort A, patients with RVF post-(LVAD) implantation (n = 31); and Cohort B, patients with RVF post-cardiotomy, heart transplant, or myocardial infarction (n = 29). The primary end-point was survival at 30 days or hospital discharge (whichever was longer).
Results:
Mean age of patients was 59 ± 15 years; 68% were males, 84% had a history of congestive heart failure, 44% had valvular disease, and 35% had pre-operative renal dysfunction. Patients received an average of 3.4 inotropes/vasopressors before the Impella RP implant. Patients were supported with the Impella RP for 4.0 ± 1.5 (0.5 to 14) days. Hemodynamics improved immediately after initiation of device support, with an increase in cardiac index from 1.9 ± 0.1 to 3.1 ± 0.2 liters/min/m2 (p < 0.001) and a decrease in central venous pressure from 19.0 ± 1 to 13 ± 1 mm Hg (p < 0.001). The overall survival at 30 days (or discharge) was 72%.
Conclusions:
To the best of our knowledge, this study represents the largest prospective study of patients with life-threatening RVF. Mechanical support with the Impella RP device in patients with RVF resulted in rapid hemodynamic improvement with reversal of shock and favorable survival.
Related Concept Videos
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Long-term Depression
Proteins: Dietary Sources and Requirements

