Related Experiment Video
Updated: Feb 5, 2026

Fabrication of White Light-emitting Electrochemical Cells with Stable Emission from Exciplexes
Published on: November 15, 2016
Comparison of white and blue light assessment of the upper and lower palpebral conjunctiva
Carolina Kunnen1, Maurice Heunen2, Cristian Mertz3
1The Ocular Surface Institute, University of Houston College of Optometry, Houston, TX, USA.
Purpose:
To compare upper and lower eyelids in terms of palpebral redness, and roughness under two lighting conditions, and assess the extent of association between redness and roughness.
Methods:
This was a cross-sectional study conducted at The Netherlands Contact Lens Congress (2016). The palpebral conjunctivae of the right, upper and lower eyelids of 250 subjects were assessed using a slit-lamp biomicroscope. White light was used to assess palpebral redness and roughness. Roughness was also assessed using cobalt blue light and fluorescein. A 5-point grading scale was used to grade the conditions. The average and maximum grades of 5 zones for the upper, and 3 zones for the lower eyelid were used in the non-parametric analysis.
Results:
A significantly higher grading in palpebral roughness was found using fluorescein with blue light, compared to using white light, for both upper and lower eyelids (p < 0.001). Upper eyelids appeared significantly rougher than lower eyelids with white and blue light (p < 0.001). Correlations between redness and roughness for upper and lower eyelids were low to moderate (p = <0.001).
Conclusion:
Palpebral roughness was scored more highly with blue, than white light, therefore these methods should not be used interchangeably. Also, roughness was more apparent in the upper eyelid, therefore eyelids should be assessed separately. Palpebral redness and roughness should be considered independent variables due to the low to moderate correlation between them. It is therefore recommended to first assess both eyelids first for redness using white light, followed by examination with fluorescein and blue light to assess roughness.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Light as Energy
Photons
A photon is a discrete electromagnetic particle or bundle of energy. Photons are characterized by their frequency, wavelength, and amplitude, similar to the properties of a wave. Waves with higher frequencies transmit more energy and have shorter wavelengths than longer wavelengths that transmit...
Arteries of the Upper Limbs
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Bones of the Upper Limb: Humerus

