Comparison between manual and automatic image registration in image-guided radiation therapy using megavoltage
Takashi Hashido1, Shinya Nakasone2, Mari Fukao2
1Division of Radiology, Department of Medical Technology, Osaka University Hospital, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan. t_hashido@hp-rad.med.osaka-u.ac.jp.
Abstract:
This study aimed to compare and assess the compatibility of the bone-structure-based manual and maximization of mutual information (MMI)-algorithm-based automatic image registration using megavoltage cone-beam computed tomography (MV-CBCT) images acquired with an imaging beam line. A total of 1163 MV-CBCT images from 30 prostate cancer patients were retrospectively analyzed. The differences between setup errors in three directions (left-right, LR; superior-inferior, SI; anterior-posterior, AP) of both registration methods were investigated. Pearson's correlation coefficients (r) and Bland-Altman agreements were evaluated. Agreements were defined by a bias close to zero and 95% limits of agreement (LoA) less than ± 3 mm. The cumulative frequencies of the absolute differences between the two registration methods were calculated to assess the distributions of the setup error differences. There were significant differences (p < 0.001) in the setup errors between both registration methods. There were moderate (SI, r = 0.45) and strong positive correlation coefficients (LR, r = 0.74; AP, r = 0.72), whereas the 95% LoA (bias ± 1.96 × standard deviation of the setup error differences) were - 1.61 ± 4.29 mm (LR), - 0.41 ± 5.45 mm (SI), and 0.67 ± 4.29 mm (AP), revealing no agreements in all directions. The cumulative frequencies (%) of the cases with absolute setup error differences within 3 mm in each direction were 80.83% (LR), 81.86% (SI), and 90.71% (AP), with all directions having large proportions of > 3-mm differences. The MMI-algorithm-based automatic registration is not compatible with the bone-structure-based manual registration and should not be used alone for prostate cancer.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Principal Stresses in a Beam
Analyzing principal stresses is crucial, especially in...
Beams with Symmetric Loadings
The M/EI...