Correlative Light- and Electron Microscopy Using Quantum Dot Nanoparticles
Published on: August 7, 2016
10.2K
Correlative Fluorescence and Scanning Electron Microscopy to Study Lymphovenous Valve Development
Xin Geng1, R Sathish Srinivasan2,3
1Cardiovascular Biology Research Program, Oklahoma Medical Research Foundation, Oklahoma, OK, USA.
Methods in Molecular Biology (Clifton, N.J.)
|September 23, 2018
Summary
Researchers developed a novel high-resolution imaging technique to study lymphovenous valves, crucial for returning lymph to circulation. This method aids in understanding valve development and potential defects linked to lymphatic dysfunction.
Area of Science:
- Cardiovascular Biology
- Lymphatic System Research
- Developmental Biology
Background:
- Lymphatic fluid returns to blood circulation exclusively through bilateral lymphovenous valves.
- These valves share structural similarities with lymphatic and venous valves.
- Defects in lymphovenous valves are implicated in lymphedema and lymphatic dysfunction models.
Purpose of the Study:
- To develop and describe a protocol for high-resolution analysis of developing lymphovenous valves.
- To precisely locate and analyze the topography of these critical valves.
Main Methods:
- Combined fluorescence microscopy and scanning electron microscopy.
- High-resolution imaging protocol for detailed valve topography analysis.
- Application to study developing lymphovenous valves.
Main Results:
- Successfully developed a protocol to visualize and analyze lymphovenous valve development.
- Achieved high-resolution imaging of valve topography.
- Enabled precise localization and detailed structural analysis.
Conclusions:
- The described protocol offers a powerful tool for studying lymphovenous valve development.
- This technique can advance understanding of lymphatic system function and dysfunction.
- Facilitates research into conditions like lymphedema by providing detailed valve morphology insights.
Keywords:
Confocal microscopyCorrelative microscopyLymphatic vasculatureLymphovenous valvesScanning electron microscopyVenous valvesMore Related Videos
Related Concept Videos
Scanning Electron Microscopy
5.5K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
5.5K
Overview of Electron Microscopy
14.7K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
14.7K
Transmission Electron Microscopy
7.3K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
7.3K
Immunogold Electron Microscopy
5.5K
Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
5.5K
Cryo-electron Microscopy
4.3K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
4.3K
Correlations
36.1K
Correlation means that there is a relationship between two or more variables (such as ice cream consumption and crime), but this relationship does not necessarily imply cause and effect. When two variables are correlated, it simply means that as one variable changes, so does the other. We can measure correlation by calculating a statistic known as a correlation coefficient. A correlation coefficient is a number from -1 to +1 that indicates the strength and direction of the relationship between...