How does anteroposterior cup placement affect bone coverage and range of motion in primary total hip arthroplasty for
Yuta Sakemi1, Keisuke Komiyama1, Kensei Yoshimoto1
1Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Background:
Due to anterior bone defects, high and/or posterior placement of an acetabular cup is often required to achieve sufficient coverage in patients with hip dysplasia. We examined whether posterior cup placement affected the postoperative range of motion (ROM) in primary total hip arthroplasty (THA).
Methods:
Using computer software, bone coverage and ROM were examined in 32 patients with unilateral osteoarthritis of the hip with Crowe type II or III hip dysplasia. We determined the cup position to satisfy cup center-edge (Cup-CE) angle ≥0° and the required ROM. The cup was placed at the anatomic hip center and moved in 2-mm increments anteroposteriorly and 10-mm increments vertically.
Results:
At vertical anatomic hip center, less than 68.8% hips fulfilled Cup-CE ≥0° regardless of anteroposterior position. Significantly more hips at higher hip center with posterior cup placement achieved Cup-CE ≥0° than hips at vertical anatomic hip center, and 10 mm higher hip center was the most suitable for achieving bone coverage. However, posterior and superior cup placement significantly decreased the flexion and IR due to early bone impingement, whereas ER and extension were not affected. A smoothing spline curve demonstrated that more posterior cup placement than 4.8 mm and 3.6 mm did not satisfy the required ROM at 10 mm and 20 mm higher hip center, respectively.
Conclusions:
Posterosuperior cup placement gained more bone coverage but decreased the range of hip flexion and internal rotation. Consequently, posterosuperior cup placement did not satisfy the required ROM.
Related Concept Videos
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Role of Affect in Interpersonal Attraction
The Influence of Affect on Cognition
The Influence of Cognition on Affect
Background and Environment Affect Phenotype
An example of how genetic background affects phenotype can be seen in horses. The Extension gene in horses is responsible for their coat color. A wild-type gene (EE) produces black pigment in the coat, while a mutant gene (ee) produces red pigment. A...
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...